Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net
Open AccessImplantology

Peri-Implant Soft Tissues

  • Dr. Jyoti GuptaP.G. Student
  • Dr. Ruchi KadianP.G. Student
  • Dr. Manesh LahoriProfessor & Dean

Department of Prosthodontics & Implantology, K.D. Dental College & Hospital, Mathura (U.P) India

Guident · Volume 14, Issue 8 (July 2021)Published July 202118 min read5 figures

ABSTRACT

For an implant restoration to closely mimic the lost dental element, it is imperative to surround the crown with healthy, gingival-like tissue. The maintenance and augmentation of the soft tissue around dental implant has emerged as an area of concern and focus. The health and vitality of an osseointegrated implant depends on the surrounding supporting tissues, which not only anchor the implant to the bone but also have the important function of providing a protective seal. The treatment modalities have evolved from socket compression post-extraction, to socket preservation with an aim to enhance the eventual peri-implant soft tissue. The triad of anatomical peri-implant characteristics, soft tissue response to the implant material, and clinical skill form the fundamental principles in augmenting soft tissue. The comparative features are of clinical relevance because it is critical to understand the behavior of the soft tissue found around the tooth and implant. This knowledge is vital from the preliminary stage of treatment planning through prosthetic rehabilitation.

KEYWORDS: Dental Implant, Peri-implant mucosa, osseointegration, graft, uncovering techniques

INTRODUCTION

The functional usefulness of oral implants lies in the fact that piercing the gingival or oral mucosa of the oral cavity establishes a transmucosal connection between the external environment and the inner dental implant. To avoid bacterial penetration that could jeopardize either initial healing or long-term behavior of implants, the early formation of a longstanding, effective barrier capable of biologically protecting the peri-implant structures is mandatory to prevent oral bacteria and their products from penetrating into the body.1 Establishment of this critical soft tissue barrier is the result of wound healing that establishes an effective interface between living tissues and a foreign body.2 The term osseointegration refers to the direct bone contact to the alloplastic metallic implant. Titanium, which has excellent biocompatibility properties in physiologic conditions, has been the most commonly used biomaterial for implants.3 The soft tissue around the implant, i.e., peri-implant mucosa, is similar in many ways to the gingiva found around the tooth.

DIFFERENCES BETWEEN PERI-IMPLANT MUCOSA AND GINGIVAL MUCOSA

Peri-implant mucosa is composed of well-keratinized oral epithelium, sulcular epithelium, and junctional epithelium, as well as underlying connective tissue. Between the implant surface and the epithelial cells are hemidesmosomes and basal lamina.4 The soft-tissue interface is made up of the epithelium and the underlying connective tissue, which includes the biologic zone known as the “biologic width,” referring to the height of the dent gingival attachment apparatus encircling the tooth. The average dimension of 2.04 mm (1.07 mm + 0.97 mm) is comprised of supra-alveolar connective tissue and junctional epithelial attachment. Functionally, in a clinical sense, there must not be any encroachment within 2 mm of the bone that surrounds the tooth. That a similar relationship of bone to overlying soft tissues exists around implants and changes in this relationship may be one of the reasons for the early crestal bone loss.5 The mucosa that encircles the fixture (implant) has more collagen and fewer fibroblasts, with a 2:1 ratio, when compared with the periodontal gingival tissue. When compared with the supracrestal vessels of a natural dental element, the supracrestal vascular topography surrounding the fixture is reduced and diversely arranged. Both the tooth and the implant have a junctional epithelium that is approximately 2 mm long.

Clinical figure

In humans, recent data showed that the biologic width around one- and two-piece retrieved implants is formed by:6

  • a crevicular epithelium composed of 4–6 layers of parakeratinized epithelial cells;
  • a junctional epithelium formed by 5–10 layers of epithelial cells, where the middle and apical portion of the JE consisted of 3–5 cells layers; and
  • a connective tissue (at the abutment area) containing few blood vessels (only from the supraperiosteal plexus), dense collagen fibres, and reduced number of fibroblasts (when compared to the lamina propria of the gingiva).

Regarding to the dimensions of the biologic width around these implants, the following can be expected:5,6

  • Mean overall dimension of the biologic width: 2.5 mm for one- and 3.3 mm for two-piece implants, where this difference was influenced by the connective tissue attachment.
  • Sulcus depth (SD): 0.3 mm for both one- and two-piece implants.
  • Junctional epithelium: 1.0 mm for both one- and two- piece implants.
  • Connective tissue attachment: 1.2 mm for one- and 1.9 mm for two-piece implants.

AESTHETIC PREDICTABILITY

The keratinized gingival tissue provides a tight fibrous collar that surrounds the implant, sealing off the bacteria from the depth of the peri-implant sulcus. This allows for easier plaque control for the patient and during periodic maintenance recall visits. Peri-implant tissue that resembles the keratinized gingival on the adjacent natural teeth is important in the aesthetic zone. The re-creation of ideal soft tissue profiles (particularly in the papillary areas) around implants is more predictable in areas of single edentulism then in multiple implant sites. Regarding the aesthetics of the gingival tissues around an implant, “Four factors are important:7

  1. the width and position of the attached gingiva;
  2. the buccal volume of the alveolar process;
  3. the level and configuration of the gingival margin; and
  4. the size and shape of the papillae.”

HEALING PROCESS

After installation of the transmucosal implant component, the healing of the connective tissue wound involves four distinct processes:

  1. Formation and (hopefully) adhesion of a fibrin clot to the implant surface,
  2. Adsorption of extracellular matrix proteins and subsequently of connective tissue cells to the implant surface,
  3. Transformation of the clot into granulation tissue.
  4. Migration of epithelial cells on top of the fibrin clot/granulation tissue.8,9

Through its capacity to proliferate and to move on surfaces, the epithelium found at the border of the incision crosses over the bridge of the fibrin clot/granulation tissue that rapidly starts forming after implant/abutment installation. Upon reaching the surface of the implanted component, it moves in the corono-apical direction, giving rise to a junctional epithelium about 2 mm long.10,11 In the initial healing phases, the quality and stability of the fibrin clot adhesion to the surface of the transmucosal components probably play a role in the formation and positioning of the junctional epithelium.12 The presence of granulation tissue adhering to the surface of transmucosal implant components is considered the principal factor that stops the epithelium from moving further apically.13 The role of the connective tissue in preventing epithelium downgrowth has been clearly demonstrated in animal models.14,15 The epithelium stops migrating in an apical direction because of the interaction between the soft tissue and the layer of titanium oxide.16 It seems that mature connective tissue interferes more effectively than granulation tissue with epithelial downgrowth.17 Once the epithelial cells have reached the implant surface, their attachment occurs directly via a basal lamina (<200 nm) and the formation of hemidesmosomes.18

JUNCTIONAL EPITHELIUM

It is generally recognized that the epithelium lining the peri-implant sulcus is similar to the junctional epithelium adjacent to teeth: it shares many structural, ultrastructural, and functional characteristics with the corresponding gingival tissue. Studies indicate that the epithelium surrounding dental implants possesses patterns of differentiation and function similar to gingival epithelium.19

CONNECTIVE TISSUE INTERFACE

In contrast, connective tissue attachment to implant components is different from the attachments observed for teeth. In periodontal tissues, cementum lines the root until enamel is reached, thus offering a substrate in which bundles of collagen fibers can deeply insert. These bundles reinforce the gingiva and provide the high cohesive strength to the dentogingival attachment that is necessary for maintaining its architecture and integrity at repeated trauma due to mastication. With endosteal dental implants, due to the absence of cementum and to the solid nature of transmucosal implant components, there is no true anchorage of supra-alveolar connective tissue, but only a brittle adhesion.16 As a consequence, the connective tissue adhesion at implant has a poor mechanical resistance compared to that of natural teeth. In other words, the gingiva at implants can hardly be qualified as attached. Because the connective tissue interface is considered of paramount importance in supporting the epithelium and blocking its apical migration, this lack of mechanical resistance can endanger the prognosis of dental implants. Tearing at the connective tissue/implant interface could occur as a consequence of mastication or a lack of soft tissue stability, which could then induce an apical migration of the junctional epithelium, bone resorption, and pocket formation or gingival recessions.20

CLINICAL CONSEQUENCES

PROBING DEPTH

Periodontal probing depth is basic diagnostic tools used to measure clinical attachment level (CAL), pocket depth, and width of the attached gingiva. Peri-implant probing provides an assessment of different parameters such as bleeding on probing, suppuration, and exudation from the sulcus and peri-implant tissues. Clinical probing depth is higher around implants versus teeth, as the probe tip ends apically to the junctional epithelium into the connective tissue close to the bone crest. In humans, it was confirmed that 0.5-1.4 mm deeper measurements are generally found at implants.21 These results are the consequence of the brittle adhesion of connective tissue at implant components, illustrating that at implants the probe tip ends somewhere in the connective tissue and that the significance of probing at implants and at teeth is different.

SOFT TISSUE STABILITY/INSTABILITY

Several studies have examined changes in soft tissue levels after implant placement. No significant difference could be determined between the 2-stage and the 1-stage surgical approaches nor between one or two-piece implants.22 One clinical study23 reported 1.3-mm recession from 1 month to 1 year, then an additional loss of 0.4 from 1-3 years. Another24 found 1.6 mm of mean recession at the mandible versus 0.9 mm at the maxilla.

INFLUENCE OF TRANSMUCOSAL COMPONENTS ON SOFT TISSUE BARRIER FORMATION

CHEMICAL COMPOSITION

The reaction of cells and tissues to implanted foreign bodies depends on the material’s properties and its behavior on contact with the body fluids. It is mandatory to place at the transmucosal level a biocompatible material to which tissues can adhere. It must be noted that the chemical composition of the bulk material is sometimes significantly different from that of the surface that is at the interface with the living tissues: some materials demonstrate a surface oxidation (such as titanium, which exhibits a surface layer of titanium oxide), whereas the mode of preparation or of sterilization of others will result in chemical contamination of the surface. Commercially pure titanium is the only material that has proven his biocompatibility toward the soft tissues in long term clinical studies. Some favorable clinical data have become available for zirconium and aluminum oxide. In contrast, animal studies have shown that dental porcelain or gold is less biocompatible and should be avoided. Materials such as resins and composites cannot be recommended.

SURFACE CONTAMINATION

The ultimate goal of cleaning procedures should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography, either after the fabrication process, after handling in the dental laboratory, or when transgingival components are reused. Although specific protocols have been developed, it proves to be rather difficult to effectively clean a contaminated titanium surface, most probably because of the strong binding of proteins and amino acids.25 This could negatively alter the biocompatibility. It should be noted that it is most unlikely to alter the composition of the transmucosal part of one-piece implants, which will therefore always be biocompatible with currently commercially available one-piece systems.

INFLUENCE OF IMPLANT DESIGN ON SOFT TISSUE BARRIER

In a one-piece implant the transmucosal component facing the soft tissues makes part of the implant. In a two-piece implant the transmucosal component dedicated at soft tissue integration is a separate part from the implant body. The interface between the transmucosal component and the implant is generally located in the neighborhood of the alveolar bone level.

Using experimental implants with either a one-piece or a two-piece design, Hermann et al.26 showed significantly higher apical migration of the soft tissues and marginal bone resorption with two-piece implants, suggesting a role for the subgingival position of the abutment/implant interface (so-called micro gap) on tissue remodeling. It must be noted that all two-piece implants in this experiment were clinically and histologically surrounded by an intense inflammatory process.

It has been shown that the seal provided by a locking taper connection at the implant/abutment interface effectively impairs bacterial leakage. But it has not been clearly shown that the bacterial contamination of the internal components of some two-piece implant systems27 is responsible for the inflammatory cell infiltrate seen at the abutment/implant interface. An intentional or unintentional disconnection of abutments is possible at two-piece implants. Based on results by Hermann et al., an unintentional abutment loosening will lead to a disruption of the soft tissue integration and to increased bone remodeling.26 It also has been shown that repeated intentional abutment disconnection and reconnection after alcoholic disinfection induce an apical repositioning of the soft tissues and marginal bone resorption.28 A single shift of a healing abutment and replacement by a final abutment proved to induce no marginal bone remodeling.

INFLUENCE OF TRANSMUCOSAL COMPONENT DESIGN ON THE SOFT TISSUE BARRIER

The positive soft tissue behavior with the particular transmucosal design evaluated in the present study is linked to a combination of three primary factors.

  1. First, the circumferential macro groove creates a void chamber in which a blood clot forms and that provides space for soft tissue regeneration. The result is a nonsurgical, localized thickening of the soft tissues.
  2. Second, the highly curved profile allows increased soft tissue-to-implant interface length, facilitating a biological seal of 3 mm despite a shorter crown-to-implant distance.
  3. Third, after maturation of the soft tissues, a ring-like seal (Figure 1) is created that could stabilize the connective tissue adhesion and functionally mimic the effect of Sharpey’s fibers at teeth (Figure 2).

Clinical figure

Figure 1: Soft tissue ring

Clinical figure

Figure 2. A-C, A concave design at the transmucosal level can provide mechanical stabilization of the peri-implant soft tissues

SURGICAL AND PROSTHETIC PARAMETERS INFLUENCING PRECOCIOUS SOFT TISSUE BARRIER FORMATION

Because epithelial cells will migrate on top of the fibrin clot to reach the implant and close the wound, the stability of the fibrin clot adhesion to the implant/abutment is of crucial importance at very early stages of healing after transmucosal component connection. Any detachment of the clot will allow contamination by saliva and, consequently, apical migration of the junctional epithelium. The following parameters can be hypothesized to have a major impact on early soft tissue barrier formation.

  • Size of the exposed blood clot: The smaller the gap, the sooner the epithelial cells will reach the implant component. Therefore, a careful flap adaptation is recommended.
  • Mechanical stability of the wound borders: Any mobility of the flap can tear off the brittle adhesion of the fibrin clot to the transmucosal implant components. Emergence of the implant into alveolar mucosa should be avoided and means to improve initial soft tissue stability should be promoted, such as the use of retentive abutments and/or minimally invasive surgical approaches avoiding large reflection of the periosteum (Figure 3).
  • Pressure of provisional removable prosthesis: If a removable prosthesis leans on the peri-implant soft tissues, masticatory movements will repeatedly destroy the fragile adhesion of the fibrin clot and induce a rapid apical migration of the biological width.

Clinical figure

Figure 3. A, Minimally invasive surgery for implant placement ensures high initial stability of the peri-implant soft tissues and a minimal blood clot. B and C, The healing is stabilized and improved (1 week after implant placement)

SURGICAL AND PROSTHETIC PARAMETERS INFLUENCING THE STABILITY OF AN ESTABLISHED SOFT TISSUE BARRIER

The interface between implant components and the connective tissue located between the junctional epithelium and the bone has very poor mechanical resistance, even in the absence of any negative event during healing and on biocompatible materials. This structural difference as compared to natural teeth explains why the periodontal probe penetrates deeper in peri-implant tissues than in the periodontium, and most probably why implants display a high frequency of gingival recession. Other consequences include the following:

  • Impression procedures: Due to the absence of inserted collagenous bundles, overly deep placement of a retraction cord can tear off the soft tissue barrier and produce deleterious effects, as can injection of impression material under overly high pressure.
  • Cementation material: Comparable detachment of the brittle soft tissue barrier is often produced by the injection of cementation material at crown/bridge placement. Because this material is not biocompatible, an apical reformation of the biological width will follow (Figure 4).
  • Abutment disconnection: When a biocompatible abutment (for instance, a titanium healing abutment) is disconnected for prosthetic reasons, the adhering soft tissues are torn off. The number of disconnections should be kept to a minimum and the disconnected components should not be placed in a toxic medium because they may be covered by cells from the soft tissue barrier.

Clinical figure

Figure 4. Subgingival injection of cementation material induce bone loss for the apical reformation of a soft tissue barrier

MATERIAL CHEMISTRY

It is mandatory to place at the transmucosal level a material to which tissues can adhere.

  • Titanium is the only material that has proven its biocompatibility with the soft tissues in long-term clinical studies.
  • Some favorable clinical data are available for zirconium and aluminum oxide.
  • Animal studies have shown that dental porcelain and gold are less biocompatible and should be avoided. Materials such as resins and composites currently cannot be recommended.
  • The surface of the core material can be contaminated, altering the composition of the interface.

It should be noted that the transmucosal part of one-piece implants are unlikely to be altered and will therefore always be biocompatible with currently available one-piece systems.

SURFACE TOPOGRAPHY

Results indicating that surface roughness and surface texture in the micrometer range may have an impact on the early events of healing by influencing attachment, orientation, proliferation, and metabolism of epithelial and connective tissue cells are available only for in vitro and animal studies.

  • Some roughened titanium surfaces seem to improve the formation of a superficial fibrin network, which could hypothetically be positive for the initial stability of the interface and impair epithelial cell downgrowth.
  • In vitro and in vivo studies tend to indicate that epithelial cell adhesion rates are lower on rough titanium surfaces than on machined titanium.
  • Animal studies show that micromachined grooved surfaces of appropriate dimensions can improve connective tissue ingrowth and inhibit epithelial downgrowth.

SUMMARY

Dental implants pierce the oral mucosa and enter the oral cavity, thus establishing a transmucosal connection between the external environment and the inner parts of the body. To avoid bacterial penetration through this transmucosal piercing, the early formation of a long-standing effective barrier is of paramount importance. Soft tissue conditions around the implants must be always evaluated, especially when it comes to anterior regions with higher esthetic demands. The final presence of good papillae and gingival scallop surrounding the implant(s) depends on several other, previously mentioned factors. The carefully customized anatomical shape of the temporary prosthesis should start molding the surrounding peri-implant soft tissues as soon as possible. It is important to evaluate the degree of maturation of the soft tissue when exerting strategically located pressure to plot the peri-implant gingival profiles.

A mature thick tissue can withstand higher degrees of pressure when compared with still-healing thin tissue, which could react to the push with a sudden undesirable recession. The triad of anatomical peri-implant characteristics, soft tissue responses to the implant material, and clinical skill form the fundamental principles in augmenting soft tissue.

REFERENCES

  1. Abrahamsson I, Berglundh T, Wennstrom J, Lindhe J: The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog, Clin Oral Implants Res 7:212-219, 1996.
  2. Charles E. Babbush, Jack A. Hahn, Jack T. Krauser, Joel L. Rosenlicht. Dental Implants The art and science (2nd edition). Saunders, an affiliate of Elsevier Inc., 3251 Riverport Lane Maryland Heights 2001:167-180
  3. Räisänen L, Könönen M, Juhanoja J, et al. Expression of the cell adhesion complexes in epithelial cells seeded on the biomaterial surfaces. J Biomed Mater Res. 2000;49(1):79-87.
  4. James RA, Schultz RL. Hemidesmosomes and the adhesion of the junctional epithelial cells to metal implants—a prelimnary report. Oral Implantol. 1974;4(3):294-302
  5. Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol. 2002;73(3):322-333.
  6. Ricardo J, Gabriela G, Elton Z, Paulo G., Magda F, Jose A. R., Carlo M, Giovanna I., Adriano P., Jamil A.S. Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws. BioMed Research International 2014 (3):850120
  7. Gilberto Sammartino, Gaetano Marenzi, Alessandro Espedito di Lauro, and Guerino Paolantoni. Aesthetics in Oral Implantology: Biological, Clinical, Surgical, and Prosthetic Aspects. Journal of Biomedicine and Biotechnology 2014(3):850120
  8. Descouts J, Aronsson BO: Influence of surface configuration on adsorption of molecules. In Lang N, Karring T, Lindhe J, editors: Proceedings of the 3rd European Workshop on Periodontology, Berlin, 1999, Quintessence, pp 30-40.
  9. Dibart S, Warbington M, Su MF, Skobe Z: In vitro evaluation of the implant-abutment bacterial seal: the locking taper system, Int J Oral Maxillofac Implants 20:732-737, 2005.
  10. Listgarten MA: Soft and hard tissue response to endosseous dental implants, Anato Rec 245:410-425, 1996.
  11. Lindhe J, Berglundh T: The interface between the mucosa and the implant, Periodontology 2000 17:47-54, 1998.
  12. Lowenguth RA, Polson AM, Caton JG: Oriented cell and fiber attachment systems in vivo, J Periodontol 64:330-342, 1993.
  13. Listgarten MA: Soft and hard tissue response to endosseous dental implants, Anato Rec 245:410-425, 1996.
  14. Squier CA, Collins P: The relationship between soft tissue attachment, epithelial downgrowth and surface porosity, J Periodontol Res 16:434-440, 1981.
  15. Chehroudi B, Gould T, Brunette DM: The role of connective tissue in inhibiting epithelial downgrowth on titanium-coated percutaneous implants, J Biomed Mat Res 26:493-515, 1992.
  16. Berglundh T, Lindhe J, Ericsson I, et al: The soft tissue barrier at implants and teeth, Clin Oral Implants Res 2:81-90, 1991.
  17. Chehroudi B, Gould T, Brunette DM: The role of connective tissue in inhibiting epithelial downgrowth on titanium-coated percutaneous implants, J Biomed Mat Res 26:493-515, 1992.
  18. James RA, Schultz RL: Hemidesmosomes and the adhesion of junctional epithelial cells to metal implants—a preliminary report, Oral Implantol 4:294-302, 1974.
  19. Carmichael RP, McCulloch CA, Zarb GA: Quantitative immunohistochemical analysis of keratins and desmoplakins in human gingiva and peri-implant mucosa, J Dent Res 70:899-905, 1991.
  20. Rompen E, Domken O, Degidi M, et al: The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: a literature review, Clin Oral Implants Res 17(Suppl 2):55-67, 2006.
  21. Bragger U, Burgin WB, Hammerle CH, Lang NP: Associations between clinical parameters assessed around implants and teeth, Clinical Oral Implants Res 8:412-421, 1997.
  22. Small PN, Tarnow DP: Gingival recession around implants: a 1-year longitudinal prospective study, Int J Oral Maxillofac Implants 15:527-532, 2000.
  23. Adell R, Lekholm U, Rockler B, et al: Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study, Int J Oral Maxillofac Surg 15:39-52, 1986.
  24. Ekfeldt A, Eriksson A, Johansson LA: Peri-implant mucosal level in patients treated with implant-supported fixed prostheses: a 1-year followup study, Int J Prosthodont 16:529-532, 2003.
  25. Rowland SA, Shalaby SW, Latour RA Jr, von Recum AF: Effectiveness of cleaning surgical implants: quantitative analysis of contaminant removal, J Appl Biomat 6:1-7, 1995.
  26. Hermann JS, Buser D, Schenk RK, Cochran DL: Crestal bone changes around titanium implants. A histometric evaluation of unloaded non submerged and submerged implants in the canine mandible, J Periodontol 71:1412-1424, 2000a.
  27. Persson LG, Lekholm U, Leonhardt A, et al: Bacterial colonization of internal surfaces of Branemark system implant components, Clin Oral Implants Res 7:90-95, 1996.
  28. Abrahamsson I, Berglundh T, Lindhe J: The mucosal barrier following abutment dis/reconnection. An experimental study in dogs, J Clin Periodontol24:568-572, 1997.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Jyoti Gupta, Dr. Ruchi Kadian, Dr. Manesh Lahori. Peri-Implant Soft Tissues. Guident. 2021 Jul;14(8). Available from: https://guident.net/articles/implantology/peri-implant-soft-tissues.html

Related articles

More in Implantology

All 232 articles
Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.