Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net
Open AccessProsthodontics

Accuracy of One-Step and Two-Step Impression Techniques with Polyvinyl Siloxane (PVS) Material: A Narrative Review

  • Dr. Shubham ChavhanP.G. Student
  • Dr. Rashmi ChaharP.G. Student
  • Dr. Manesh LahoriVice Chancellor-KD Univ.

Department of Prosthodontics and Crown & Bridge, K.D. Dental College & Hospital, Mathura, UP, India

Guident · Volume 19, Issue 8 (July 2026)Published July 20266 min read

ABSTRACT

Accurate impression making is fundamental to the success of fixed prosthodontic restorations. Polyvinyl siloxane (PVS) impression materials are widely used because of their excellent dimensional stability, elastic recovery, and fine detail reproduction. Among the conventional elastomeric impression techniques, one-step and two-step approaches remain the most commonly employed methods. However, controversy persists regarding which technique provides superior dimensional accuracy and clinical predictability. This review evaluates the current evidence concerning the accuracy of one-step and two-step impression techniques using PVS material. Recent studies indicate that both techniques provide clinically acceptable results, although the two-step technique often demonstrates improved wash bulk control and enhanced marginal accuracy in long-span restorations. Conversely, one-step techniques offer reduced chairside time and simplified clinical procedures. Factors such as spacer thickness, tray rigidity, interabutment distance, impression material viscosity, and operator skill significantly influence impression accuracy. Recent digital analyses and three-dimensional superimposition studies have further clarified the dimensional behavior of PVS impressions. Within the limitations of available literature, both techniques remain reliable for routine prosthodontic procedures; however, the two-step technique may provide greater precision in complex restorative situations.

Keywords: Polyvinyl siloxane, PVS, impression techniques, one-step impression, two-step impression, dimensional accuracy, prosthodontics.

INTRODUCTION

Accurate impression making is one of the most critical procedures in fixed prosthodontics because the success of indirect restorations depends largely on the precise transfer of intraoral structures to the dental laboratory. Errors occurring during impression making can lead to marginal discrepancies, poor internal fit, occlusal inaccuracies, and eventual prosthetic failure. Polyvinyl siloxane (PVS), also known as vinyl polysiloxane, has become one of the most preferred elastomeric impression materials because of its excellent dimensional stability, superior elastic recovery, tear resistance, and ability to reproduce fine details.1

Two principal techniques are commonly used with PVS materials: the one-step (simultaneous putty-wash) technique and the two-step (reline or wash) technique. In the one-step technique, putty and light-body materials are polymerized simultaneously, whereas in the two-step technique, a preliminary putty impression is made first and later relined with light-body material. Despite widespread clinical use, disagreement persists regarding which technique provides superior dimensional accuracy and marginal fidelity.2

This review aims to critically analyze the literature regarding the dimensional accuracy and clinical efficacy of one-step and two-step PVS impression techniques.

PROPERTIES OF POLYVINYL SILOXANE IMPRESSION MATERIALS

PVS materials were introduced to overcome the limitations associated with hydrocolloids and polysulfide materials. Their major advantages include:

  • Excellent dimensional stability
  • High elastic recovery
  • Superior tear strength
  • Accurate detail reproduction
  • Pleasant odor and taste
  • Multiple viscosity options

The hydrophobic nature of conventional PVS materials was initially considered a limitation; however, newer hydrophilic formulations have improved wettability and clinical handling.3

One-Step Impression Technique

The one-step or simultaneous technique involves the concurrent use of heavy-body/putty and light-body wash materials. The wash material is syringed around the prepared tooth while the tray loaded with putty or heavy-body material is seated immediately.

Advantages

  • Reduced chairside time
  • Single seating procedure
  • Lower risk of distortion during reseating
  • Improved patient comfort

Disadvantages

  • Uncontrolled wash bulk
  • Possible hydraulic displacement of wash material
  • Increased risk of bubbles and voids
  • Technique sensitivity

Several studies have reported acceptable clinical accuracy with one-step PVS impressions. A recent clinical investigation demonstrated that one-step impressions showed dimensional accuracy comparable to two-step methods, with only minimal differences between the groups.4

Two-Step Impression Technique

The two-step technique involves fabrication of an initial putty impression followed by relining with light-body material after spacer creation. Spacers may be created using polyethylene sheets, wax spacers, or bur relief.

Advantages

  • Better control of wash thickness
  • Improved marginal detail reproduction
  • Reduced polymerization shrinkage effects
  • Enhanced accuracy in long-span restorations

Disadvantages

  • Additional chairside time
  • Possibility of improper reseating
  • Greater technique sensitivity
  • Potential distortion during secondary seating

Recent three-dimensional analyses demonstrated that the two-step technique provides greater accuracy in cases involving increased interabutment distance.5

Comparative Accuracy of One-Step and Two-Step Techniques

DIMENSIONAL ACCURACY

Dimensional stability remains the primary parameter for evaluating impression accuracy. Multiple in vitro and clinical studies have compared the two techniques with varying outcomes.

A 2025 investigation evaluating interabutment distances reported that the two-step technique produced significantly greater accuracy in larger edentulous spans compared with the one-step technique.5

Conversely, other studies found minimal or statistically insignificant differences between the two methods, suggesting that both techniques may be clinically acceptable when performed correctly.4

A literature review published in the Saudi Dental Journal concluded that evidence remains controversial because some studies favor one-step techniques while others support two-step methods.2

FACTORS INFLUENCING IMPRESSION ACCURACY

1. Wash Space Thickness

Uniform wash thickness is critical for minimizing polymerization shrinkage. Two-step techniques generally provide better wash space control.

2. Interabutment Distance

Increasing the distance between prepared abutments may negatively affect impression accuracy, particularly in one-step impressions due to material distortion.

3. Tray Rigidity

Rigid custom trays reduce distortion and improve dimensional stability compared with flexible stock trays.

4. Impression Material Viscosity

The viscosity combination of putty/heavy body and light body significantly affects flow and adaptation around preparation margins.

5. Operator Technique

Improper tray seating, delayed pouring, inadequate adhesive application, and contamination can compromise impression quality.

Recent Advances in Impression Analysis

Contemporary studies increasingly use digital scanners and three-dimensional superimposition software to assess impression accuracy. These technologies provide highly precise quantitative analysis compared with conventional linear measurements.

Modified two-step approaches such as membrane techniques and wiggling-motion techniques have also been introduced to improve wash material distribution and reduce distortion. Research indicates that modified two-step techniques may enhance accuracy compared with conventional one-step procedures.

CLINICAL IMPLICATIONS

For short-span fixed prostheses and routine clinical situations, both one-step and two-step PVS impression techniques provide clinically acceptable results. However, in cases involving multiple prepared abutments, long-span restorations, or subgingival finish lines, the two-step technique may provide superior marginal accuracy and dimensional stability.

Clinicians should focus on proper tray selection, controlled wash bulk, adequate gingival management, and adherence to manufacturer recommendations to maximize impression accuracy.

CONCLUSION

Both one-step and two-step impression techniques using polyvinyl siloxane materials demonstrate acceptable dimensional accuracy and remain clinically reliable for fixed prosthodontic procedures. Although recent evidence suggests that two-step techniques may offer improved precision in complex restorative cases and long-span edentulous situations, one-step techniques continue to provide predictable results with greater procedural simplicity and reduced chairside time. The ultimate accuracy of PVS impressions depends not only on the technique selected but also on factors such as wash thickness, tray rigidity, material handling, and operator expertise. Further randomized clinical trials and digital comparative studies are necessary to establish definitive clinical guidelines.

REFERENCES

  1. Ghoraishian SA, Khataminia M, Shahramian Z, Zare M, Mohaghegh M. Evaluation of the effect of distance between dental abutments on the accuracy of one-step and two-step impression techniques with polyvinyl siloxane (PVS) material. Clin Exp Dent Res. 2025;11(1):e70100.
  2. Alshamrani R, Aldegheishem A, Eldwakhly E, Mostafa MS. One-step versus two-step impression techniques; a literature review. The Saudi Dental Journal. 2019 Jan 1;31:S72.
  3. Waldecker M, Rues S, Rammelsberg P, Bömicke W. Dimensional accuracy of Novel Vinyl Polysiloxane compared with Polyether impression materials: an in Vitro Study. Materials. 2024 Aug 27;17(17):4221.
  4. Anwar R, Hanif F, Alvi S, et al. Comparison of linear dimensional accuracy between one step and two-step impression technique. J Popul Ther Clin Pharmacol. 2025;32(3):329-335.
  5. Ghoraishian SA, Khataminia M, Shahramian Z, Zare M, Mohaghegh M. Evaluation of the Effect of Distance Between Dental Abutments on the Accuracy of One?Step and Two?Step Impression Techniques With Polyvinyl Siloxane (PVS) Material. Clinical and Experimental Dental Research. 2025 Feb;11(1):e70100.
  6. Zappi A, Papazoglou E, Anagnostou M. Is a wiggling-motion modified two-step impression technique as accurate as conventional techniques in restorative dentistry? Dent J (Basel). 2023;11(5):139.
  7. Khuda-E-Dad, Yazdanie N, Hussain S, et al. Comparison of linear dimensional accuracy between one step and two-step impression technique using polyvinyl siloxane impression material. J Gandhara Med Dent Sci. 2022;9(3).
  8. Waldecker M, Rues S, Rammelsberg P, Bömicke W. Dimensional accuracy of novel vinyl polysiloxane compared with polyether impression materials: An in vitro study. Materials. 2024;17(17):4221.
  9. AlQahtani MQ. One-step versus two-step impression techniques: A literature review. Saudi Dent J. 2019;31(Suppl):S72.
  10. Lawson NC, Burgess JO, Litaker MS, et al. Clinical efficacy of polyvinyl siloxane impression materials using the one-step two-viscosity impression technique. J Prosthet Dent. 2015;114(2):217-222.
  11. The effect of one-step vs. two-step impression techniques on long-term accuracy and dimensional stability when the finish line is within the gingival sulcular area. Br Dent J. 2014;216:639.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Shubham Chavhan, Dr. Rashmi Chahar, Dr. Manesh Lahori. Accuracy of One-Step and Two-Step Impression Techniques with Polyvinyl Siloxane (PVS) Material: A Narrative Review. Guident. 2026 Jul;19(8). Available from: https://guident.net/articles/prosthodontics/accuracy-of-one-step-and-two-step-impression-techniques-with-polyvinyl-siloxane-pvs-material-a-narrative.html

Related articles

More in Prosthodontics

All 444 articles
Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.