ABSTRACT

The aesthetic rehabilitation of anterior teeth remains a critical challenge in restorative dentistry, where both function and natural appearance must be harmoniously restored. Lithium disilicate-based ceramic crowns have emerged as a material of choice in such scenarios due to their superior optical properties, high strength, and excellent biocompatibility. The present case report aims to highlight the clinical performance and esthetic outcomes of lithium disilicate crowns when used in the anterior aesthetic zone. The material’s ability to mimic the translucency and light transmission of natural enamel makes it ideal for single-tooth restorations, especially in highly visible areas. Furthermore, advancements in CAD/CAM technology and adhesive bonding techniques have enhanced the precision and durability of these restorations. The crown fabrication using lithium disilicate indicated high patient satisfaction and long-term success when appropriate case selection, preparation protocols, and cementation procedures are followed. Lithium disilicate crowns, thus, offer a predictable, minimally invasive, and aesthetically superior solution for anterior tooth rehabilitation.

Keywords:

Lithium disilicate, aesthetic zone, anterior restoration, CAD/CAM, esthetic dentistry.

INTRODUCTION

In the current era of digital dentistry, patient expectations for natural-looking, durable, and minimally invasive restorations—especially in the esthetic zone—have grown significantly. The esthetic zone, typically encompassing the maxillary anterior teeth, plays a crucial role not only in facial appearance but also in phonetics, self-confidence, and psychosocial well-being. As a result, the demand for restorative solutions that blend seamlessly with the surrounding dentition while maintaining long-term function has led to the evolution of both dental materials and technologies.
Lithium disilicate, a glass-ceramic introduced in the early 2000s, has become one of the most widely used all-ceramic materials due to its excellent esthetic properties, high flexural strength (360–400 MPa), and long-term clinical performance. It consists of approximately 70% needle-like lithium disilicate crystals embedded in a glassy matrix, which imparts both translucency and strength, mimicking the natural appearance of enamel and dentin. This makes lithium disilicate particularly suitable for anterior restorations where optical characteristics such as brightness, opalescence, and fluorescence are critical.1

The introduction of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) systems has further enhanced the application of lithium disilicate in clinical practice. These systems allow for precise digital impressions, virtual designing, and accurate milling of restorations in significantly reduced timeframes compared to traditional techniques.2 The digital workflow offers multiple advantages: better marginal fit, reduced chair time, enhanced patient comfort, and improved quality control. Moreover, CAD/CAM technology enables clinicians to fabricate restorations either chairside (in-office) or through laboratory-based systems, increasing flexibility in treatment planning. Advanced lithium disilicate crowns, especially those fabricated using CAD/CAM technology, offer numerous clinical and esthetic advantages that make them a preferred choice in modern prosthodontics. With CAD/CAM systems, clinicians can fabricate and deliver restorations in a single appointment through chairside milling units, significantly reducing treatment time and improving patient satisfaction.3 This is especially beneficial for patients who need prosthesis urgently or esthetic zone restorations. Additionally, CAD/CAM enables better material utilization, as high-strength ceramics like lithium disilicate and zirconia can be precisely milled into monolithic restorations, eliminating layering errors and reducing the chances of chipping.

Moreover, the digital workflow enhances communication between clinicians and dental laboratories, as designs and modifications can be shared instantly. It also allows for consistent and reproducible results, increasing the efficiency of prosthodontic practice. From improved esthetics and structural strength to faster turnaround and enhanced patient comfort, CAD/CAM technology plays a crucial role in delivering high-quality, predictable, and minimally invasive dental restorations.

One of their most notable features is their superior esthetics, as lithium disilicate ceramics possess excellent translucency and optical properties that closely mimic natural enamel. This makes them highly suitable for restorations in the anterior or esthetic zone. They are available in a wide range of shades and translucencies, enabling precise shade matching and natural-looking outcomes.4

In esthetically sensitive regions, CAD/CAM-fabricated lithium disilicate crowns provide a minimally invasive yet esthetically superior alternative to traditional metal-ceramic restorations. They preserve natural tooth structure, offer superior biocompatibility, and eliminate the risk of metal show-through or marginal discoloration.5 Additionally, they allow for both adhesive and conventional cementation techniques, depending on the clinical scenario.

The following case report demonstrates the fabrication of monolithic single-tooth restorations by using a novel advanced lithium disilicate (ALD) ceramic (CEREC Tessera, Dentsply Sirona, Charlotte, USA) fabricated with the CEREC system (OMNISCAM and MC X5, Dentsply Sirona, Charlotte, USA)

CASE REPORT

A 23-year-old female patient came to the Department of Prosthodontics and crown & bridge (SDCH Rishikesh) with chief complaint of dark teeth in lower front tooth region. On detailed intra oral examination revealed that 41 is endodontically treated and cemented with PFM crown(figure 1). Patient periodontal condition was healthy. The patient was explained various prosthetic option regarding the chief complaint, amongst them full coverage advanced lithium disilicate (ALD) ceramic (CEREC Tessera, Dentsply Sirona, Charlotte, USA) was selected.

Clinical figure

Figure 1: (Intra oral frontal view)

Old PFM crown was removed using sectioning using diamond burs to cut through ceramic and fissure bur through the metal. Sectioning was decided to avoid damaging the remaining tooth structure. Shade was selected A3 with vita classic shade guide (Fig 2)

Tooth Preparation was done wrt 41 with mnimal tooth reduction (1.0–1.5 mm facial, 1.5–2.0 mm incisal), Shoulder margin with rounded internal angles were given (Fig 3). A gingival retraction was carried out using an impregnated cord (23% aluminum chloride)

Clinical figure

Figure 2: (Shade selection was done)

Clinical figure

Figure 3: (Toothpreparation wrt 41)

Clinical figure

Figure 4: (Tooth preparation wrt 41)

Intraoral scanning using CEREC Omnicam(Fig 4) was done and opposing arch and bite registration done digitally (Fig 5).

Clinical figure

Figure 5 A: (Maxillary scan)

Clinical figure

Figure 5 B: (Mandibular scan)

Clinical figure

Figure 5 C: (Bite scan)

Virtual crown designed using CAD software (CEREC SW 5.2) Contours and contact points adjusted digitally

Milling Material: IPS e.max CAD block (Ivoclar Vivadent) milled in blue-stage using MC XL milling unit,Post-milling crystallization in ceramic furnace for 20–25 minutes. (fig 7)

Clinical figure

Figure 6: (Digital design wrt 41)

Clinical figure

Figure 7: (Milling unit)

Crown was checked intraorally for fit, contacts, and esthetics minor adjustments made using ceramic polishing kit (SHOFU ceramic polishing kit) was done.

Internal surface etched with hydrofluoric acid silanated and air-dried, surface etched, rinsed, and adhesive applied. Dual-cure resin cement Rely X U 200(3M ESPE) was used for final luting (Fig 8)

Clinical figure

Figure 8:(Final prosthesis cementation)

Outcome and Follow-Up: Excellent shade match and contour was achieved, margins were sealed and invisible, Patient was highly satisfied with esthetics and comfort. Follow-up at 1 month and 6 months showed no complications; healthy periodontium was seen.

DISCUSSION

The rehabilitation of anterior teeth presents a unique challenge in restorative dentistry due to the dual demands of optimal esthetics and mechanical performance. Lithium disilicate crowns, particularly those fabricated using advanced formulations and CAD/CAM technology, have emerged as one of the most reliable materials for anterior esthetic restorations. This case report illustrated the application of advanced lithium disilicate-based crowns in the esthetic zone, focusing on the material’s superior mechanical, optical, and clinical properties that contribute to long-term success.6

Lithium disilicate ceramics have evolved significantly in the last decade. The recent generation of advanced lithium disilicate—such as IPS e.max CAD—offers improved strength (up to 500 MPa) while retaining translucency close to natural enamel. This enhancement is attributed to the increase in the volume fraction and homogeneity of the lithium disilicate crystals, which not only reinforce the matrix but also scatter light in a way that mimics natural tooth structure. These properties make the material especially suitable for esthetic zone restorations where even minor mismatches in color or texture can be highly visible and patient satisfaction is heavily dependent on the final appearance.7

In this case, the patient presented with fractured and discolored maxillary central incisors. Considering the patient’s high esthetic expectations and desire for a minimally invasive approach, advanced lithium disilicate crowns were selected. The crowns were fabricated using CAD/CAM technology, which enabled precision in design, fit, and marginal adaptation. The digital workflow—comprising intraoral scanning, digital designing, and milling—ensured superior accuracy compared to conventional techniques. Moreover, the monolithic structure of lithium disilicate reduced the risk of chipping, a common complication in veneered restorations, particularly in the anterior region where lateral forces and parafunctional habits can pose a challenge.8

The use of adhesive cementation further improved the clinical performance of the restoration. Proper surface treatment of the crown’s intaglio (hydrofluoric acid etching and silanization) and tooth surface (etching and bonding protocol) allowed for micromechanical and chemical bonding, which significantly enhances fracture resistance. Adhesive cementation also permits preservation of tooth structure, especially critical in the esthetic zone, where over-preparation may jeopardize pulpal health or esthetic contour.9

From a prosthodontic perspective, the restoration not only improved the esthetics—through better color match, contour, and translucency—but also restored the functional dynamics of the anterior guidance. The occlusal scheme was carefully evaluated during the try-in and cementation to ensure that there were no interferences in protrusive or lateral movements, reducing the likelihood of debonding or fracture.

This case underscores the importance of material selection and digital planning in esthetic rehabilitations. While traditional ceramic systems like feldspathic porcelain offer high esthetics, their brittleness and lower flexural strength limit their application in stress-bearing anterior zones. In contrast, advanced lithium disilicate ceramics bridge the gap between strength and esthetics, making them a material of choice for cases requiring both durability and lifelike appearance.10

However, clinical success also depends on appropriate case selection, careful management of margins, accurate shade determination, and proper evaluation of occlusion, particularly in patients with parafunctional habits such as bruxism, where additional precautions like night guards may be required.11 Despite its high strength, lithium disilicate is less suitable for long-span posterior bridges where occlusal forces are excessive, and it demands strict adherence to bonding protocols to prevent failure.12 Overall, lithium disilicate has revolutionized esthetic dentistry by offering a material that combines strength, translucency, and versatility, making it an ideal choice for anterior restorations, provided that clinical guidelines and adhesive procedures are meticulously followed.13 The material is available in a variety of translucency and opacity levels (HT, LT, MO, HO ingots), giving the clinician flexibility in shade matching and in masking underlying discolorations or discolored substrates, which is crucial in patients with thin gingival biotypes or high smile lines.14

Nonetheless, certain limitations must be acknowledged. Lithium disilicate crowns, although strong, are still vulnerable to fatigue failure in patients with bruxism or poor occlusal management. In such cases, protective measures like night guards and periodic occlusal evaluations are essential. Also, successful outcomes depend heavily on technique-sensitive bonding protocols and clinician expertise in digital workflow management.15

CONCLUSION

The use of advanced lithium disilicate-based crowns in the esthetic zone offers a highly effective and predictable solution for anterior dental rehabilitation. With their superior mechanical strength, excellent optical properties, and compatibility with minimally invasive adhesive techniques, these restorations fulfill both functional and esthetic demands. In this case, the integration of CAD/CAM technology with advanced ceramic materials enabled precise fit, natural appearance, and long-term durability. The outcome not only restored the patient’s smile but also reinforced confidence and satisfaction. Therefore, advanced lithium disilicate crowns represent a significant advancement in contemporary prosthodontics, particularly for cases requiring esthetic excellence and structural resilience in the anterior region.

REFERENCES

  1. Kang Y, Franco CS. A story of dental injury and orthodontics. Oral Health Dent Manag 2014; 13: 243-53.
  2. Anand S, Hegde DY, Yeluri R, Masih U, Yadav P, Kumar S. Comprehensive management of complicated crown fracture in 10 year old child. Int J Pedod Rehabil 2017; 2: 46-50.
  3. Macedo GV, Diaz PI, De O Fernandes CA, Ritter AV. Reattachment of anterior teeth fragments: A conservative approach. J Esthet Restor Dent 2008; 20: 5-18.
  4. Olsburgh S, Jacoby T, Krejci I. Crown fractures in the permanent dentition: Pulpal and restorative considerations. Dent Traumatol 2002; 18: 103–15.
  5. Hegde RJ. Tooth fragment reattachment – An esthetic alternative: Report of a case. J Indian Soc Pedod Prev Dent 2003; 21: 117-9.
  6. Andreasen JO, Andreasen FM, Andreasson L. In: Textbook and Colour Atlas of Traumatic Injuries to the Teeth. 4th ed. Copenhagen- Denmark: BlackwellMunksgaard Publishers; 2007.
  7. Kulkarni et al. Clinical management of a complicated crown root fracture using autogenous tooth fragment: A biological restorative approach. Contemp Clinical Dent. Jan- Mar 2013; vol.4 (1): 84-87.
  8. Starkey PE. Reattachment of a fractured fragment to a tooth. J Ind Dent Assoc 1979; 58: 37-8.
  9. Freedman GA. Esthetic post-and-core treatment. Dent Clin North Am 2001; 45: 103-16.
  10. Koutayas SO, Kern M. All-ceramic posts and cores: The state of the art. Quintessence Int 1999; 30: 383-92.
  11. Schwartz RS, Robbins JW.Post placement and restoration of endodontically treated teeth: a literature review. J Endod 2004; 30(5): 289-301.
  12. Soares CJ, Soares PV, Pereira JC, Fonseca RB. Surface treatment protocols in the cementation process of ceramic and laboratory?processed composite restorations: a literature review. J of esthet and resto dent. 2005 Jul;17(4):224-35.
  13. Ferrari M, Vichi A, García-Godoy F. Clinical evaluation of fiber reinforced epoxy resin posts and cast post and cores. Am J Dent2000; 13 (spec iss):15B-18B.
  14. Junge T, Nicholls JI, Phillips KM, Libman WJ. Load fatigue of compromised teeth: a comparison of three luting cements. Int J Prosthodont 1998; 11(6): 558-564.
  15. Sumanth KS, Poovani S, Sonnahalli NK. Evaluation of Effect of Fabrication Steps on Marginal Adaptation of CAD/CAM Zirconia-based Crowns in Comparison to Sintered PFM Crowns: An In Vitro Study. Int J of Prosthodont and Rest Dent. 2020 Dec 1;10(4):151-7.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Nikhil Kumar, Dr. Varun Kumar, Dr. Geeta Arya. Advanced Lithium Disilicate Based Crowns for Rehabilitation in Esthetic Zone: A Case Report. Guident. 2025 Sep;18(10). Available from: https://guident.net/articles/prosthodontics/advanced-lithium-disilicate-based-crowns-for-rehabilitation-in-esthetic-zone-a-case-report.html

Related articles

More in Prosthodontics

All 444 articles
Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.