Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net
Open AccessProsthodontics

Causes and Solutions for Problems Associated with Impression and Cast Made from Alginate

  • Dr. Krishna KumarProfessor
  • Dr. Beena RoopakProfessor

Department of Prosthodontics including Crown & Bridge and Implantalogy, Department of Oral surgery, Rajarajeshwari Dental College and Hospital, Bangalore

Guident · Volume 13, Issue 4 (March 2020)Published March 20206 min read

Introduction

There are various reasons for rejecting alginate impressions, a brief review of causes and solutions for problems associated with impression and cast made from alginate materials are mentioned below

1. PROBLEM

Alginate sticks to the teeth.

CAUSES

Teeth being too dry, loss of protective film from teeth due to repeated impressions.

SOLUTIONS

Avoid air drying of teeth, isolate arch with gauge packs. Repeated impressions not necessary, delay impression until another day and make patient suck on sour (citrus) or candy.

2. PROBLEM

Voids in the impression

CAUSES

Poor mix of alginate, alginate did not flow to all required areas

SOLUTIONS

Wipe alginate alongside of bowl during spatulations and use mechanical spatulations under vacuum. Wipe alginate on teeth, on palate, and into vestibular areas after mouth has been isolated with gauge packs; avoid mix that is too thick or too thin by using correct water-powder ratio; measure alginate by weight not volume; avoid deterioration of alginate by heat or moisture contamination.

3. PROBLEM

Peripheral under extension of the impression

CAUSES

Alginate did not flow into peripheral areas or poor mix of the alginate, tray too small because of which material not carried into vestibule or might be due to incorrectly seating of the tray.

SOLUTIONS

Use tray with 3-5mm clearance or centre the tray with handle pointing straight out of mouth; retract lips with fingers so correct position of tray can be seen; seat the tray so that borders go below gingival marginal areas; avoid overly large trays which will interfere with coronoid processes of mandible; pull out cheeks and retract the lips and make patient to protrude tongue before final seating of tray.

4. PROBLEM

Alginate tears when impression is removed

CAUSES

Mix of alginate is too thin or too thick; Impression removed from mouth too soon or due to inadequate bulk of alginate and deteriorated alginate used. Prolonged or insufficient spatulation and improper removal from mouth might be one of the causes.

SOLUTIONS

Use water-powder ratio recommended by manufacturer; measure alginate by weight instead of volume; avoid deterioration of alginate by heat or moisture. Keep impression in mouth two to three minutes after it loses it tackiness; select tray with three to five mm clearance, center tray properly; store bulk alginate in airtight containers at room temperature; avoid rocking or teasing out of impression; remove with snap.

5. PROBLEM

Lack of detail or grainy appearance

CAUSES

Prolonged or insufficient spatulation.

SOLUTIONS

Spatulate by hand or mechanically as recommended by manufacturer.

6. PROBLEM

Alginate sets before tray is completely seated.

CAUSES

Mixing water too warm; particle of dental stone in mixing bowl; prolonged spatulation of alginate; use of deteriorated alginate; layer of material painted in mouth too thin; fast set alginate used might be the reason.

SOLUTIONS

Use lower water temperature; if more working time required. Use different mixing bowls and spatula for alginate and stone and proper spatulation technique. Store at room temperature; avoid moisture contamination by measuring & sealing all contents of bulk containers of alginate. Wipe larger amounts onto teeth and into vestibules; introduce tray immediately by having tray filled before painting in mouth.

7. PROBLEM

Patient gags when tray is selected for fit or impression is made.

CAUSES

Patient is fearful & lacks confidence in dentist. Alginate flowing out of tray and into patients throat; patient is tense or patient may have severe gag reflex.

SOLUTIONS

Proceed with confident in well organized manner; use simple explanation; avoid talk about gagging. Seat patient upright with occlusal plane parallel with floor; correct maxillary tray with modeling plastic; avoid overfilling of tray. Instruct patients to keep eyes open& focused on a small object; instruct patients to breathe through nose at normal rate. Ask patient to hold breath while tray is fit or corrected; use the “leg –lift” procedure, use fast –set alginate or accelerate the set of alginate by using warmer water.

8. PROBLEM

Alginate displaced by saliva in the palate

CAUSES

Mucinous saliva not removed from palate. Excessive secretion by palatal mucous glands.

SOLUTIONS

Have patient use astringent mouthwash and cold water rinse; use warm gauze pads to milk palatal glands, followed by cold pads to constrict gland openings.

9. PROBLEM

Alginate pulled away from the tray

CAUSES

Alginate not forced under rim lock

SOLUTIONS

Use small increments and force alginate into rim lock areas.

10. PROBLEM

Cast has rough surface

CAUSES

Incompatibility between alginate and dental stone; insufficient spatulations of stone; sticking of alginate to teeth; saliva retained on impression; water left on impression; poor mix of alginate; insufficient spatulation;use of single pour technique.

SOLUTIONS

Change brand of alginate or stone to obtain compatible combination; spatulate until smooth homogenous mix is attained.Rinse in running water until alginate has rough feel; use camel hair brush to remove saliva; use dry dental stone as a disclosing agent; blot water with dry tissue paper; avoid use of compressed air; use two stage pour technique.

11. PROBLEM

Surface of cast has chalky appearance

CAUSES

Incompatible alginate stone combination; film of stone slurry on cast after dry cast trimmed on model trimmer, Impression left contact with cast for prolonged period.

SOLUTIONS

Change brand of alginate or stone to obtain compatible combination; thoroughly soak cast in clear slurry water before trimming and rinse periodically in clear slurry water while trimming; separate impression from cast 45 to 60 min after first pour.

12. PROBLEM

Cast has a soft surface

CAUSES

Too much water in mix of stone; use of inverted single stage pour technique; use of moisture contaminated stone. Water or stone powder added to improper water powder ratio mix after mixing has been started or stone spatulated too long.

SOLUTIONS

Use acceptable water powder ratio; measure stone by weight instead of volume; use two stage pour technique; premeasure stone and store in air tight container; avoid use of open bins for stone storage; measure correct amount of stone for acceptable water-powder ratio.

13. PROBLEM

Cast breaks when impression separated from the cast

CAUSES

Premature removal of impression from cast; too much water in mix stone; use of single stage pour technique; water left in the impression; alginate left in contact with cast overnight.

SOLUTIONS

Separate cast from impression 45-60 min after first pour; measure water and weigh powder for correct water powder ratio; use two stage pour technique; blot all water with dry tissue paper

14. PROBLEM

Voids on surface of the cast

CAUSES

Air trapped in mix of stone because of inadequate or improper mixing; cast poured too rapidly or due to over vibration during pouring

SOLUTIONS

Shift powder into water to avoid air entrapment; spatulate or mechanically mix stone under vacuum for fifteen to twenty seconds; lightly vibrate mix until no more air bubbles come to surface; add small increments to stone to the same posterior extension of impression with light vibration and allow stone to flow slowly to fill areas of impression; use light vibration only, flowing stone should not bounce.

15. PROBLEM

Under extension of the cast

CAUSES

Cast over trimmed; hamular notch,retromolar pad vestibular areas may be obliterated; alginate did not cover all peripheral areas of the impression.

SOLUTIONS

Care to be taken while trimming of the casts on model trimmer to avoid removal of critical areas; fill impression completely & cover all peripheral border areas with 5-6 mm of stone during first stage of pour

16. PROBLEM

Cast is inaccurate; not a true reproduction of the anatomy of the mouth

CAUSES

Loss of moisture content of impression because of syneresis, resulting in release of strains; distortion in impression caused by its movement during gelation; impression removed before the completion of gelation;strains induced in impression during its removal from mouth;use of non rigid impression tray; distortion in palate due to failures to correct tray

SOLUTIONS

Pour cast immediately after removal of impression from mouth; avoid excessive drying of impression; do not store impression in water or other solution; do not wrap impression in wet paper towel; remove impression with a snap, applying force directly along long axis of teeth; avoid use of tray that lack rigidity; retract lip for good visibility when setting tray; Correct palatal area of maxillary tray with modeling plastic.

References

  1. Rodney D. Phoenix, David R. Cagna, Charles F. Defrest. Stewarts Removal partial Prosthodontics.4th edition. Quintessence publishing co, inc
  2. Anusavice KJ, Shen C, Rawls HR. Philips science of dental materials, 12th edition Elsevier inc, St Louis; 2013
  3. CraigRG, Powers JM.Restorative dental materials,11th edition Elsevier,St Louis;2002.
  4. CraigRG.Review of dental impression materials.Adv Dent Res.1988; 2:51.
  5. GladvinMA, BagbyMD.Impression materials. Clinical aspects of dental materials, Lippincott Williams and Wilkins.
  6. MillerMW.Syneresis in alginate impression materials.Br Dent J.19785;139;425-430

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Krishna Kumar, Dr. Beena Roopak. Causes and Solutions for Problems Associated with Impression and Cast Made from Alginate. Guident. 2020 Mar;13(4). Available from: https://guident.net/articles/prosthodontics/causes-and-solutions-for-problems-associated-with-impression-and-cast-made-from-alginate.html

Related articles

More in Prosthodontics

All 444 articles
Vol. 13, Issue 3 · February 2020

Full Mouth Rehabilitation-a Case Report

The treatment involving the facial esthetics is not only demanding for the patient but also challenging for the clinician. It involves skill of the prosthodontist in maintaining the health…

Dr. Shraddha Tamore

Vol. 13, Issue 6 · May 2020

Rapid Prototyping in Dentistry-

The advent of Rapid prototyping has opened new prospects in medical field, especially dentistry with its accuracy and speed. Rapid prototyping is an additive manufacturing technology that…

Dr. M. Sumati

Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.