Maxillofacial Rehabilitation of a Patient Recovered from Noma
ABSTRACT
Noma, also known as cancrum oris, is an infectious disease that destroys the oro-facial tissues and neighboring structures in its fulminating course, and has a mortality rate as high as 70–90% if not promptly treated.1 It is a rapidly progressive, polymicrobial, opportunistic infection that leads to destruction of the hard and/or soft facial tissues. The causative factors include malnutrition (particularly A-and B-vitamins) or dehydration, poor oral hygiene, unsafe drinking water, proximity to unkempt livestock, an immunodeficiency disease, including AIDS.
The extraoral facial and intraoral deformities have to be surgically reconstructed or a combined intraoral obturator and facial prosthesis have to be made. It is very challenging and special care is of utmost importance. This clinical report highlights the rehabilitation of a lateral midfacial defect with a two piece prosthesis that included an intraoral obturator and an extraoral silicone facial prosthesis retained with the use of Cobalt-Samarium magnets.
INTRODUCTION
Noma is an infectious disease that destroys the oro-facial tissues and neighboring structures in its fulminating course, and has a mortality rate as high as 70–90% if not promptly treated.1 It is a rapidly progressive, polymicrobial, opportunistic infection that occurs during periods of compromised immune function. Fusobacterium necrophorum and Prevotella intermedia are thought to be key players in the process and interact with one or more other bacterial organisms (such as Borrelia vincentii, Porphyromonas gingivalis, Tannerella forsynthesis, Treponema denticola, Staphy lococcus aureus, and nonhemolytic Strept ococcus spp).2 It is very rare now, even in developing countries. It predominantly affects children between 2-16 years and is known to occur in association with poor nutrition and exanthematous infection. The chronic sequelae of the acute disease process leaves behind extensive deformities and often requires reconstructive surgery. It has a high mortality rate but with the introduction of antibiotics as a form of therapy, a higher survival rate has been achieved. The complex type of deformity usually requires staged reconstructive procedures.3
Facial prosthesis is generally considered over surgical reconstruction to restore function and appearance in patients with facial defects. Retention of the prosthesis is challenging due to its size and weight. Retention can be achieved by using medical grade adhesives, resilient attachments, clips and osseointegrated implants. It can also be connected to obturator by magnets.4 This clinical report highlights the rehabilitation of a lateral midfacial defect with a two piece prosthesis that includes an intraoral obturator and an extraoral silicone facial prosthesis retained with the use of Cobalt-Samarium magnets.
CASE REPORT
A 43 year-old diabetic man reported to the Department of Prosthodontics, Dr. D. Y. Patil Dental College and Hospital, Pimpri, Pune with a combined intraoral/facial defect for a definitive prosthetic rehabilitation. Clinical examinations revealed the intraoral areas to be covered for retention and the areas to be relieved, and showed complete healing of the surgical wound; prior to which the prosthetic phase commenced (Figure 1). The margins of the defects and tissues within were healthy and normal. The intraoral palatal defect involved the first quadrant, exposing the right maxillary antrum and intraoral examination revealed missing 13-17 along with displaced 12. The defect corresponded to Aramany’s Class II tripodal configuration (Figure 2).
Radiological examinations revealed loss of right maxillary sinus floor, lateral nasal wall and adjoining area (Figure 3). The range of mandibular movements was found to be normal. Speech intelligibility and deglutition were severely affected since the patient's tongue could not make effective functional contacts due to lack of anatomic boundaries during speech and deglutition.4
Hence, prosthetic rehabilitation was planned with a definitive acrylic hollow bulb obturator and silicone facial prosthesis retained with magnets. Fabrication of such prosthesis was planned in two sections – first, the obturator was fabricated, followed by fabrication of silicone facial prosthesis and then magnets were incorporated for the stabilization of the two when in place.
Fabrication of intraoral obturator prosthesis:
Prior to making an impression of the defect, petroleum jelly gauze was used to pack off the nasal portion of the defect and to block out the undercut region. An impression of maxillary arch along with the palatal defect was made in irreversible hydrocolloid impression (Tropicalgin, Zhermack, Italy) material and a diagnostic cast was retrieved out of it (Figure 4). After blocking the undercuts in defect area of the cast, a layer of wax spacer was adapted and 3mmx3mm were cut out at several areas for tissue stops of the shim that was going to be fabricated by lost salt technique. Autopolymerising resin layer was adapted and allowed to set. Then salt was filled and an acrylic layer that acted as a lid was made. Then, this shim was placed on the cast and a wax-up of the obturator base was done on which teeth were arranged and guided into occlusion with the aid of opposing stone model on a semi-adjustable articulator (Hanau H2). Following this, the wax-up was chilled and tried in mouth for occlusal adjustments (Figure 5).
Retentive clasps were made - circumferential clasp on 11 and 23, Adam’s clasp on 26 and an arrowhead clasp between 24 and 25. These were incorporated to the waxed-up obturator, and then that was flasked, dewaxed and a definitive hollow-bulb obturator was fabricated using heat-cure acrylic resin with the shim in place (Figure 6).
After processing an aperture was made on the mesial aspect of the bulb and posterior to molar tooth to remove the salt, thus making the obturator hollow. The apertures were closed with autopolymerising resin. The obturator was tried intraorally so as to relieve areas under pressure and pain (Figure 7). The patient was instructed about oral hygiene, maintenance and use of obturator.
Fabrication of extraoral silicone facial prosthesis:
A facial moulage impression was made with irreversible hydrocolloid (Tropicalgin, Zhermack, Italy) to record the facial defect along with surrounding normal structures. For this purpose, an impression compound frame was adapted on the face and then hard modelling wax was adapted to confine the alginate. Opened gauze squares were placed on the alginate for mechanical retention for the rigid plaster backing (0.25 inch), which is necessary for removal of the impression without distortion. When the plaster sets, the impression is removed and a definitive cast was poured with Type II gypsum (Kalstone; Kalabhai Karson, Mumbai, India) (Figure 8).
The facial prosthesis was sculpted with base plate wax. The wax pattern was evaluated by positioning it on the patient's face with the obturator in place and modified (Figure 9). Investing of the wax pattern was done in Type II gypsum to form a mold for packing the silicone. After complete dewaxing, a silicone adhesive (2-butanone, Voco, Germany) was applied and the mold was packed with silicone (Maxillofacial silicone system, Factor II, Lakeside, AZ, USA) and colored using intrinsic stains and flocks (Silicone Coloring Kit; Factor II, Lakeside, AZ, USA) selected to match the patient's skin color. The silicone was kept for 24 hours at room temperature. After deflasking and finishing, extrinsic stains were applied and characterization was done by embedding hair for moustache (Figure 10).
Incorporation of Magnets:
The obturator was placed intraorally and the silicon prosthesis was placed in the extraoral defect, this showed the area of contact and helped to plan the magnet positions. After the magnet positions were decided, Cobalt samarium magnets were attached on the supero-lateral aspect of the bulb with autopolymerizing resin so that they can contact the magnets on the extraoral prosthesis for mutual retention.4
The prostheses were delivered to the patient and final occlusal adjustments were completed (Figure 11). Movement of the prosthesis was minimized by maximal distribution of the occlusal force in centric and eccentric jaw positions. Elimination of premature occlusal contacts and wide distribution of stabilizing components resulted in diminished stress created by horizontal forces. The patient experienced marked improvement in speech intelligibility and deglutition after the placement of the intraoral obturator.
During the prosthesis insertion appointment the maxillary obturator was placed intraorally and the facial prosthesis was positioned extraorally against the obturator magnet (Figure 12). The patient was given strict instructions pertaining to use, care and maintenance of the prostheses. He was told for recall every 4-6 months.
DISCUSSION
Maxillofacial defect results in communication between the oral and nasal cavity. It causes difficulty in deglutition, nasal regurgitation, speech and unesthetic appearance, leading to significant psychological problems. Unlike a conventional prosthesis, additional factors should be taken into consideration such as method of impression, materials to be used in laboratory procedures, prosthesis design, method of connection, direction of insertion and removal, esthetic factors, and maintenance protocol.4
A correct understanding of the remaining anatomic structures, which can be utilized for retention, is a must. Various methods of retention for facial prostheses have been described in the literature; they include eyeglasses, eye patches, extensions from the denture that engage desirable tissue undercuts, medical grade adhesives, magnets, and osseointegrated implants.5-7 The introduction of rare-earth permanent magnets made of alloys such as Neodymium-Ferro-Boron and Cobalt-Samarium has resulted in magnets of very small dimensions. Tarnish and corrosion can be overcome by coating these magnets with nickel, gold and titanium.8 Although osseointegrated implants may provide the most reliable prosthesis retention but additional surgeries, expenses, inadequate available bone, and prior radiation to the area may contraindicate this type of treatment.9,10
Mutual retention of the intra- and extra- oral prosthesis can be successfully achieved through magnets. The force needed to separate magnets was designated as breakaway load expressed in terms of grams. The value of breakaway load is inversely proportional to the distance of separation and inclination between the magnets. These magnets are wholly biocompatible in the human body and exert no deleterious effects in human tissue. Inert magnetic field is harmless to human body and can be safely used for patients with cardiac pacemaker. There may be a gradual decrease in retentive force upon usage while some open field uncoated magnet exhibits significant cytotoxic effects which may be attributed to the release of corrosion by products from them. Therefore, magnets should be replaced as early as signs of corrosion develop.
Problem of two piece prosthesis is that the mobility of intraoral obturator can make facial prosthesis mobile especially during functions but the light weight of the prosthesis can alleviate this problem.11 Many methods and materials have been used to fabricate a hollow obturator such as salt, sugar and ice. A lightweight prosthesis which was fabricated in this case by lost salt technique not only counteracted forces due to gravity but also enhanced speech intelligibility.12,13
CONCLUSION
The rehabilitation of a patient with a combined intraoral-extra oral defect has been presented. A two-piece prosthesis that included an intraoral obturator and extra oral silicone facial prosthesis was fabricated. Magnets were incorporated into each unit to mutually retain each segment of the prosthesis. Marked improvement in appearance, speech intelligibility and deglutition were noted.
REFERENCES
- Cyril O. Enwonwu, William A. Falkler, Jr., Emmanuel O. Idigbe, Bab M. Afolabi, Mahmood Ibrahim, Daniel Onwujekwe, Olaide Savage, and Valli I. Meeks. Pathogenesis of cancrum oris (noma): Confounding interactions of malnutrition with infection. Am J Trop Med Hyg 1999;60(2):223–232.
- Neville, Brad. Oral and Maxillofacial Pathology (3rd ed.). Saunders Book Company. pp. 062008. 5.11.
- Seema Rekha Devi & Mituban Gogoi. Aesthetic restoration of facial defect caused by cancrum oris: A case report. Indian J Plastic Surg July-December 2003 Vol 36 Issue 2: 131-133.
- Saurav Banerjee, Surender Kumar, Amit Bera, Tapas Gupta, and Ardhendu Banerjee. J Adv Prosthodont. Magnet retained intraoral-extra oral combination prosthesis: a case report. Nov 2012; 4(4): 235–238.
- Thomas K. Prosthetic rehabilitation. London: Quintessence Publishing; 1994. p. 93-103.
- Menneking H, Klein M, Hell B, Bier J. Prosthetic restoration of nasal defects: Indications for two different osseointegrated implant systems. J Facial Somato Prosthet 1998;4:29-33.
- Worthington P, Brånemark PI. Advanced osseointegration surgery applications in the maxillofacial region. Carol Stream, Il, Quintessence; 1992. p. 307-26.
- Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Prosthet Dent 1991;66:536-40.
- Arcuri MR, LaVelle WE, Fyler E, Jons R. Prosthetic complications of extraoral implants. J Prosthet Dent 1993;69:289-92.
- Roumanas E, Nishumura R, Beumer J, Moy P, Weinlander M, Lorant J. Osseointegrated implants: Six-year follow-up report on the success rates of craniofacial implants at UCLA. Int J Oral Maxillofac Implants 1994;9:579-85.
- Patil PG. Modified technique to fabricate a hollow light-weight facial prosthesis for lateral midfacial defect: a clinical report. J Adv Prosthodont 2010;2:65-70.
- Matalon V, LaFuente H. A simplified method for making a hollow obturator. J Prosthet Dent 1976;36:580-2.
- Schneider A. Method of fabricating a hollow bulb obturator. J Prosthet Dent 1978;40:351.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Hemal Patel Mumbai. Maxillofacial Rehabilitation of a Patient Recovered from Noma. Guident. 2015 Sep;8(10). Available from: https://guident.net/articles/prosthodontics/maxillofacial-rehabilitation-of-a-patient-recovered-from-noma.html