Recent Advances in Maxillofacial Prosthodontics
Royal Dental College, Palakkad, Kerala, India
ABSTRACT
Advancements in the field of dentistry is inevitable and it had been widely invaded by technology. The advent of latest technologies is not only seen in d field of surgery and imaging but it is also seen in the field of data acquisition and materials used for rehabilitation. The latest into this race is the use of tissue engineering using stem cells.
Keywords: 3D photography, alginate, digital photography, rapid prototyping, stem cells, tissue regeneration.
INTRODUCTION
Glossary of prosthodontic terms defines maxillofacial prosthesis as “the branch of prosthodontics concerned with restorations and replacement of stomatognathic and craniofacial structure with prosthesis that may be removed on a regular or elective basis.”1
Medical imaging technologies have evolved from x – Ray radiology to more advanced and refined medical imaging modalities such as computerized tomography (CT), magnetic resonance imaging (MRI), and laser digitizing. These new technologies provide detailed three-dimensional pictures of the anatomy of the area of interest and therefore valuable data for diagnostic and therapeutic usage. Techniques have been developed, together with software and hardware, to represent the data in 3D on a 2D screen. Given the visualization provided by sophisticated software packages, the fabrication of physical models may seem superfluous. Head-mounted displays, stereoscopic glasses, and holograms have been employed to complement the 2D screen to provide more realistic representations of 3D volume models. Advancements have not only occurred in imaging and prosthesis fabrication but also in impression materials and attempts have also made to regenerate the lost parts.
The advancement in materials involves impression materials and prosthetic materials.
RECENT ADVANCEMENTS IN IMPRESSION MATERIALS AND TECHNIQUES
- Alginates for maxillofacial prosthesis ( J series )
- Elastomers
- Digital photography
- Laser digitization
NEWER ALGINATES
1. J -603 Special formula alginate (fig 1)
- Special formula for ophthalmic usage
- Neutral pH prevent irritation
- Fine grain particles – consistent, creamy, bubble free material
Fig 1
2. J – 6390 alginate (fig 2)
- Ideal for hands, feet small objects
- Bright pink
- White – in two minutes
- 3 minutes
Fig 2
3. J – 6370 (fig 3)
- Formulated for socket duplication and smaller impressions
- Sets in 3 min 20 sec in 700 F water
Fig 3
4. J – 6380 alginate (6 minutes) (fig 4)
- Head and larger areas
- Smooth, strong, firm and flexible
Fig 4
5. J – 604 Fiber gel alginate (fig 5)
- Formulated for professional high – production, high end details
- 40 % stronger than conventional
- Adds tear strength, prevents run and drips
- Retains moisture, Reduces shrink rate
- Remains soft and flexible
- Delayed pouring without loss of details
Fig 5
6. J – 611 – R - alginate retarder (fig 6)
- Alginate retarding agent
- More control over their alginate
Fig 6
ELASTOMERS
FX – 302- 1 clone silicone impression material (fig 7)
- Ideal for quick impression and multiple pour
- Available as two parts
- 8 minutes RTV
- Expensive
Fig 7
IMPORTANCE OF PHYSICAL MODELS
The construction of physical models is often necessary. Physical models are attractive to surgeons because they offer the opportunity to hold the model in hand and view in a natural fashion, thus providing surgeons a direct, intuitive understanding of complex anatomic details which otherwise cannot be obtained from imaging on screen.
The use of physical models also creates improved prerequisites for planning and simulation of complex surgery. With a physical model at hand, a surgeon is able to exercise on the model with the usual surgical tools, enabling him/her to rehearse different surgical plans realistically. Based on this, surgery can be simulated in a way that is not possible even with the latest visualization technologies. Such an intensive planning of surgical procedures allows the selection of the best technical approach. Additionally, the communication between the surgeon and the patient before a complicated surgical procedure can be clearly improved by the use of physical models.
RECENT ADVANCEMENTS IN PROSTHESIS FABRICATION
- Materials of the 3rd millennium2
- Remerdale E.H listed some properties of the materials of the 3d millennium:
- Translucent and should have pigmentation ability to match any skin colour Increased elongation
- Increased tear strength
- Should be easily moldable
- Cured with light
- Readily accept extrinsic colouration
- No need for high temperature moulds
Fig 8
MDX 4 – 4210 (fig 9)
- Medical grade silicone elastomer
- Improved coloration and edge strength
- Addition polymerization and no by products
- Cured material has adequate tear strength
- And colour stability
RAPID PROTOTYPING3
A physical model can be manufactured based on X-ray CT or MRI data. Several methods can be employed to fabricate a physical prototype. These methods can be divided into two categories: subtractive and additive. They all start with a 3D computer aided design (CAD) model of the anatomical area, which usually can be derived from X- ray CT or MRI data.
The subtractive technique used is the conventional numerically controlled (NC) machining, generally milling. In this case the shape of the model is milled from a block of polyurethane or other foam. The advantages include low material costs and the possibility that these models can be worked on with surgical instruments. This method has two limitations. One limitation results from milling machines, which have restricted motion capability. Complex geometries are difficult to program and can result in tool/workpiece collisions, and they are often the cases in medical application. The other limitation lies in the materials used to fabricate the physical model. The materials employed should be hard, tough, and sterilizable. Klein et al. employed polyurethane foam to fabricate the milled model in pediatric craniofacial surgery. Quality of the milled models was limited because the polyurethane foam is brittle and soft and the material is not sterilizable.
Additive methods are advantageous to fabricate the physical models of anatomical details. The main advantage of rapid prototyping is that medical models can be created that have undercuts, voids, and complex internal geome- tries such as neurovascular canals or sinuses. They can also be translucent and the internal geometries can be easily seen. The main problem with milling is that very small geometries are difficult to make, and fixturing is a problem and access to undercuts and complex shapes is difficult.
The development of rapid prototyping (RP) systems has led to the creation of customized 3-D anatomic models that exhibit a level of complexity unknown with CNC-based equipment primarily because RP methodologies use an additive process of building an object in layers defined by a computer model that has been virtually sliced. This allows for production of complex shapes with internal detail and undercut areas. By incorporating 3-D scanning as a modeling technique, the user obtains a digital model of the proposed anatomic part.
The digital data can then be digitally manipulated to create contact-free reproduction of facial surface features, mirror anatomic parts, and produce models in various scales to compensate for patient growth or material distortions. The main advantages of RP technologies are reduced operating time and improved implant conformity, which lead to a greater quality of implant, reduced mortality rates, greater patient satisfaction, and a lower cost of treatment in the long term. It becomes a common practice to fabricate RP physical models from scanned data during the diagnostic and therapeutic periods. As a result, many published papers have discussed the applications of RP technologies in craniofacial and maxillofacial fields.4
Fig 9: Silicone prostheses from conventional model (left) and RP-generated model (right).
TISSUE ENGINEERING
Stem cells are unique types of cells that have specialized capacity for self-renewal and potency to give rise to one or sometimes many different cell types. Rehabilitating facial expression, articulation, chewing and swallowing is more delicate and complex. This has now gained momentum with the introduction of stem cells into regenerative dentistry. The two main properties of stem cells are:
- Self – renewal
- Capacity to undergo numerous cycles of cell division ( 40 – 60 Population doublings )
- Potency
- Differentiation capacity
Fig 10
Tissue engineering is mainly composed of 3 units (fig 10) : stem cells, signaling molecules and a scaffold5 Stem cells can be divided as-
- Embryonic stem cell
- Adult stem cell
- Heamatopitc stem cell
- Mesenchymal stem cell
- Induced pluripotent stem cell
- Stem cells from the oro-maxillofacial region
Stem cells can be isolated and characterized from Dental pulp stem cells (DPSCs)
- Stem cells from exfoliated deciduous teeth (SHED)
- Periodontal ligament stem cells (PDLSCs)
- Stem cells from apical papilla (SCAP)
- Dental follicle progenitor cells (DFPCs)
ADVANTAGES OF DENTAL STEM CELLS ARE
- They have high plasticity.
- They can be cryopreserved for longer period (Ideal for stem cell banking).
- They show good interaction with scaffold and growth factors.
CLINICAL APPLICATION OF STEM CELLS
Stem cells can be used to correct larger craniofacial defect by regeneration of bone and soft tissues. Surgical correction done by transfer of tissue results in:
- Loss of unique function of lost part
- Donor site morbidity
- Scarring
- Infection
Stem cells form dental pulp has the potential for osteoblast formation and is a good source of bone formation. Stem cells from bone marrow and dental pulp can be used to correct larger defects. Stem cells from exfoliated deciduous teeth (SHED) have the ability to promote wound healing.
CONCLUSION
The advancement of dentistry with the involvement of technology has led to innovations in the field of maxillofacial prosthodontics. Newer impression materials with better reproducibility,tear resistance and lesser tissue irritation has lead to better reproduction of the defect tissues. Newer materials and techniques have improved the esthetics, life like appearance and ease in duplication with incorporation of even the slightest and minutest details. The research wih stem cells are proving to be more biocompatible and hold a promising future in maxillofactial rehabilitation.
REFERENCES
- The Glossary of Prosthodontic Terms. The Journal of Prosthetic Dentistry. 2005;94(1):10-92.
- Mahajan H, Gupta K. Maxillofacial Prosthetic Materials: A Literature Review. JOFR. 2012;2:87-90.
- Bibb R, Eggbeer D, Evans P. Rapid prototyping technologies in soft tissue facial prosthetics: current state of the art. Rapid Prototyping Journal. 2010;16(2):130-137.
- Madhav V, Daule R. Rapid Prototyping and its Application in Dentistry. J Dent Allied Sci. 2013;2(2):57.
- Patil A, Merchant Y, Nagarajan P. Tissue Engineering of Craniofacial Tissues – A Review. J Regen Med Tissue Eng. 2013;2(1):6.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Rohit Raghavan, Dr. Justin Baby, Dr. Shreshta Sathish Department of Prosthodontics. Recent Advances in Maxillofacial Prosthodontics. Guident. 2016 Apr;9(5). Available from: https://guident.net/articles/prosthodontics/recent-advances-in-maxillofacial-prosthodontics.html