Retrieval of Separated Instrument Using U-File and Dental Operating Microscope Followed by Root Canal Treatment
Department of Conservative Dentistry and Endodontics, K. D. Dental College and Hospital, Mathura, Uttar Pradesh, India
ABSTRACT
During endodontic treatment many kind of unwanted procedural errors can occur at any stage of treatment. The most common being separation of instrument especially endodontic files, inside the root canal. This in-turn hampers canal disinfection leading to failure of treatment. Thus removal of instrument should be considered as the treatment of choice, if possible. With the help of U-files and dental operating microscope instruments (DOM) can be easily retrieved. This case report aims to present the successful retrieval of instrument using U-file and DOM.
INTRODUCTION
Instrument separation, is a common mishap that occurs during endodontic treatment. It causes root canal obstruction and inhibits the process of shaping and cleaning. Using nickel titanium (NiTi) rotary instruments during root canal preparation does not reduce the risk of separation because this instrument is often overused or used incorrectly.1
Several factors determine the prognosis of broken file removal, such as the type of separated instrument, canal depth, pulp status, and canal infection. NiTi fragments are more difficult to remove than stainless steel ones because they are prone to further breakage when using an ultrasonic instrument for retrieval. If the fragment is located deeper in the canal, a significant amount of dentin is lost in the process of fragment retrieval, resulting in reduced root strength. Fragment blockage commonly occurs in the apical third of the root canal due to the curvature. The presence of periapical pathology also leads to poor prognosis if the root canal is not disinfected adequately because of fragment blockage.2
A high-magnification dental microscope and enhanced lighting can be used to identify the instrument fragments. Ultrasonic instruments have a small tip and their abrasive coatings enables them to remove dentin in a precise manner. They can be used to retrieve broken files conservatively by removing the root canal wall to loosen the fragment.3 A U-file can be used to retrieve a broken instrument in a root canal by moving it counterclockwise around the broken instrument. This method increases the success of retrieval while preserving sound dentin tissue. This case report describes the retrieval of separated instrument using U- Files and Dental operating microscope.
CASE REPORT
A female patient of 50 years reported with the complaint of pain in her lower front tooth region since 2 month. Patient gave the history of previous root canal treatment in the same region which was not completed by the previous dentist. On clinical examination the tooth 33 had evidence of access opening and the cavity was open. Tooth was tender on percussion. On radiographic examination, radiopaque material was seen in almost the entire canal suggesting of separated fragment of instrument. (Figure 1)
From the clinical and radiographic examination diagnosis of incomplete RCT with separated instrument and symptomatic apical periodontitis w.r.t 33 was made. Informed consent was taken from the patient and the access cavity was refined for proper access to the canals. Under dental operating microscope the separated instrument was visualized and straight line access was created.
First a no 10 hand K- file (Dentsply Maillefer, OK, USA) was used to bypass the instrument along with EDTA gel. The file was used in pecking motion and tip of file was slightly curved. Then a U-File no 15 (Mani Inc.) was taken in an ultrasonic tip and file was moved along the edges of the instrument. Care was taken not to touch the separated instrument as it would lead to the breakage of the U- File. The U-file was moved in back and forth and up and down direction which led to cutting of the dentin adjacent to the separated instrument. After few movements copious irrigation with 5ml of 2.5% NaOCl and normal saline was done.
After using the 15 no U-File, the separated instrument was still attached firmly so no 20 U-File was used. Care was taken not to remove much dentin from the ultrasonic tip. The tip was slowly advanced apically loosening the separated instrument in the canal. Continuous irrigation was done which resulted in the flushing out of the fragment. (Figure 2)
An IOPAR was taken to verify that the separated instrument has been removed properly. (Figure 3)
Working length was determined using 15 no hand K file radiographically and canal was prepared using rotary Protaper Gold system (Dentsply Maillefer, Ballaigues, Switzerland) upto size F2. Copious irrigation using 5ml of 2.5% NaOCl, 5ml of 17% EDTA and normal saline. Calcium hydroxide dressing was given to the patient for 7 days and cavity was sealed. After 7 days patient was recalled and tooth was asymptomatic so the canal was obturated using Gutta Percha and AH Plus sealer (Figure 4).
Cavity was restored using composite resin and further prosthesis was placed which was required on the adjacent teeth also. (Figure 5)
DISCUSSION
The use of an operating microscope and small-diameter U-File in endodontic treatment can improve minimally invasive root canal preparation and increase the safety of instrument extraction. In general, the success rate in instrument retrieval is high for separated instruments located before the canal curvature, moderate for those located in the curvature, and reduced for those located beyond the curvature.4 The use of an ultrasonic instrument assisted by a microscope is a gentler method of treating broken files than other methods. It can erode dentin structure more conservatively and is less likely to damage root structure and periodontal tissues. Visualization and accessibility to the separated instrument play a significant role in retrieval. Retrieval of a broken file can be done in a dry condition to provide better visibility when using the dental microscope. This method may prevent procedural accidents.5
However, ultrasonic instruments can damage periodontal tissue by heat generation if the temperature rises above 10oC on the external root surface. Therefore, it is recommended that an irrigating solution be applied when using an ultrasonic instrument.6 In this case, irrigating solution being used was 2.5% NaOCl which can dissolve the organic portions of the smear layer to ensure better visualization.
CONCLUSION
Fractured endodontic file instruments remain a problem in any root canal treatment. Use of ultrasonic and dental operating microscope is a reliable option for the removal of separated instrument.
REFERENCES
- Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod 2006; 32:1031-43.
- Spili P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod 2005; 31: 845-50.
- Subrata A, Hardini N. Removing a fractured instrument from the root canal using ultrasonic tips. Sci Dent J. 2019; 3: 95–9.
- Sharma D. Broken instrument retrival: a case report. Heal Talk. 2013; 5: 32–3.
- Hindlekar A, Kaur G, Kashikar R, Kotadia P. Retrieval of Separated Intracanal Endodontic Instruments: A Series of Four Case Reports. Cureus. 2023;15:e35694.
- Ultrasonic vibration: temperature rise on external root surface during broken instrument removal. Hashem AA. J Endod. 2007;33:1070–1073.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Snehil, Dr. Ajay Kumar Nagpal, Dr. Nima W. Mosobi. Retrieval of Separated Instrument Using U-File and Dental Operating Microscope Followed by Root Canal Treatment. Guident. 2025 Jan;18(2). Available from: https://guident.net/articles/endodontics/retrieval-of-separated-instrument-using-u-file-and-dental-operating-microscope-followed-by-root-canal.html