Micro Geometrical Considerations in Dental Implants
Department of Prosthodontics and Implantology, K.D. Dental College & Hospital, Mathura, U.P
ABSTRACT
During the last decades, several changes of paradigm have modified our view on how biomaterials' surface characteristics influence the bioresponse. After becoming aware of the role of a certain microroughness for improved cellular contact and osseointegration of dental titanium implants, the likewise important role of surface energy and wettability was increasingly strengthened.
The long-term success of dental implants largely depends on rapid healing with safe integration into the jaw bone. Short and long-term success of dental implants depends on the geometry and surface topography.
However, research findings have recently shown that osteogenic cells respond to chemical and morphological changes at a nanoscale on the surfaces, including titanium dioxide nanotube arrangements, functional peptide coatings, fluoride treatments, calcium–phosphorus applications, and ultraviolet photofunctionalization. Some of the nano-level modifications have not yet been clinically evaluated. However, these modified dental implant surfaces at the nanoscale have shown excellent in vitro and in vivo results, and thus promising potential future clinical use.
The aim of this literature review is to find current knowledge of dental implants focusing on MICRO GEOMETRICAL CONSIDERATIONS , designs and surface modifications and to understand which implant surfaces have more predictable clinical outcomes.
KEYWORDS - MICRO GEOMETRICAL, SURFACE MODIFICATIONS, DENTAL IMPLANTS
INTRODUCTION
Dental implants may be classified as endosseous, subperiosteal and transosteal.1-3
1. ENDOSSEOUS IMPLANTS
The first and most commonly used type of design is the endosteal (called endosseous) implant. The prefix endo means “within,” and osteal means “bone.” It is a device placed into an alveolar and/or basal bone of the mandible or maxilla that usually transected only one cortical plate. Examples of an endosteal implants:
2. SUBPERIOSTEAL IMPLANT
An implant that is placed beneath the periosteum while overlying the bony cortex. This implant was first developed by Dahl (1943) and refined by Berman (1950), who used a direct bone impression. This type of implant technique employed an implant substructure and superstructure. The custom-cast frame was placed directly beneath the periosteum overlying and fitting along the bony cortex.
Applications: To restore partially dentate or completely edentulous jaws when there was inadequate bone for endosseous implants.
Limitations: Numerous considerations, including the difficulty of retrieval.
3. Transosteal implant
Combines the subperiosteal and endosteal components. This type of implant penetrated both cortical plates and passes through the full thickness of the alveolar bone. Use of the transosteal implant has been restricted to the anterior area of the mandible and provides support for tissue-borne overdentures.
Small (1968) developed the mandibular staple implant made of a titanium alloy, which was modified by Bosker (1983), who produced the transmandibular implant (TMI) made of a gold alloy.4
Other names for transosteal implants have included staple bone implant, mandibular staple implant, and transmandibular implant.
4. EPITHELIAL IMPLANT
Inserted into the oral mucosa. The current use of “mucosal inserts” or epithelial implants is very limited.
Applications: This type was associated with a simple surgical technique where the mucosa was used as an attachment site for metal inserts placed into an acrylic denture.
Disadvantages: Painful healing process and a requirement for continuous wear. The current use of “mucosal inserts” or epithelial implants is very limited.3,4
MACROTOPOGRAPHY
This refers to the shape, outline of the implant body, the three‑dimensional structure of the implant, the presence of threads, and other modifications.5,6
IMPLANT THREADS
One of the main macroscopic characteristics is the presence or absence of implant threads. When threads are present, they are usually double‑threaded or triple‑threaded. Again, according to their shape, the threads are subdivided as V‑shaped, square, buttress, and reverse buttress.
OUTLINE OF THE IMPLANT
There are various shapes of implants available, the most common being the tapered. Other outlines include stepped, conical, and paralleled. The apex of the implant also varies between flat, pointed, and rounded.
OTHER MODIFICATIONS
Further modifications include the incorporation of ledges, flutes, indentations, grooves, and vents.
SURFACE TOPOGRAPHY
It includes macroscopic, microscopic and nanometric characteristics of the implant surface.6,7
Depending on the dimension of different surface characteristics, implant surface roughness is divided into macro, micro and nano roughness.
- Macro roughness: This feature can range from millimetres to microns. Macro roughness includes the implant geometry, including threaded screw and macro porous surface. An appropriate macro roughness can directly improve the initial implant stability and long-term fixation by mechanical interlocking of the rough surface irregularities and the bone.
- Micro roughness: Ranges from 1–10 microns and maximizes the interlocking between surrounding bone and implant surface. Studies supported by some clinical evidence suggest that the micron-level surface topography results in greater bone formation at the implant surface.
- Nano roughness: This technology uses nano-sized materials with a size of 1–100 nm on the implant surface. This microscopic roughness is believed to promote absorption of proteins and adhesion of osteoblasts hence improved osseointegration.
IMPLANT MICROGEOMETRY
The long-term success of dental implants largely depends on rapid healing with safe integration into the jaw bone. Short and long-term success of dental implants depends on the geometry and surface topography. Last decade has evidenced great development of implant surfaces in a concentrated effort to provide bone in a faster and improved osseointegration process.8,9,10
Several surface modifications include turned, blasted, acid-etched, porous sintered, oxidized, plasma-sprayed and hydroxyapatite-coated surfaces, as well as combinations of these procedures. But it is not clear whether the height of surface irregularities is more important than the distance between them and which combination of these factors could improve osseointegration.
Among the several parameters influencing the success of the implants, implant-bone interface plays an important role in prolonging the longevity and improving the function of the implant-supported prosthesis.
Roughness can be produced on the implant surfaces through the addition or subtraction procedures.
A plasma arc is a kind of addition process, which involves the deposition of bioactive Hydroxyapatite (HA) material on the surface of the implants.
Among subtraction procedures are; Polishing, Machining and Acid etching. These treatments may also be classified into mechanical, chemical, electrochemical, electropolishing, vaccuum, thermal and laser methods.
VARIOUS DENTAL IMPLANTS SURFACE MODIFICATION TECHNIQUES.
SURFACE TOPOGRAPHY
It includes macroscopic, microscopic and nanometric characteristics of the implant surface.11
Depending on the dimension of different surface characteristics, implant surface roughness is divided into macro, micro and nano roughness.
- Macro roughness: This feature can range from millimetres to microns. Macro roughness includes the implant geometry, including threaded screw and macro porous surface. An appropriate macro roughness can directly improve the initial implant stability and long-term fixation by mechanical interlocking of the rough surface irregularities and the bone.
- Micro roughness: Ranges from 1–10 microns and maximizes the interlocking between surrounding bone and implant surface. Studies supported by some clinical evidence suggest that the micron-level surface topography results in greater bone formation at the implant surface.
- Nano roughness: This technology uses nano-sized materials with a size of 1–100 nm on the implant surface. This microscopic roughness is believed to promote absorption of proteins and adhesion of osteoblasts hence improved osseointegration.
EVOLUTION OF DENTAL IMPLANT SURFACE TREATMENT
- Dental implant surface modification has been developed over the years on both commercial and research level and can be classified to the following generations11,12
- First-generation (mechanical surface modification): Surface machine grinding.
- Second generation (morphological modification): Grooving, sandblasting, chemical acid etching, laser abrasion, and anodic oxidation.
- Physicochemical active surface (third generation): Hydroxyapatite (HA) coating and chemical treatment.
- Fourth generation (biochemical active surface): Biofunctional molecules immobilization such as collagen, peptides, and bone morphogenetic protein (BMP).
- Fifth generation (biological surface): Stem cells and tissues coatings.
METHODS OF SURFACE MODIFICATIONS OF IMPLANT SURFACES
The methods employed for surface modifications of implants can be broadly classified into 3 types- mechanical, chemical and physical.
The main objective of these techniques is to improve the bio-mechanical properties of the implant such as stimulation of bone formation to enhance osseointegration, removal of surface contaminants and improvement of wear and corrosion resistance.
MECHANICAL TREATMENTS
Mechanical methods involve treatment, shaping or removal of the material from surface by means of physical forces. Mechanical treatments involve either removal of surface material by cutting or abrasive action, or the surface of the implant is deformed (and/or partially removed) by particle blasting.
The most commonly employed mechanical techniques are machining, polishing, and blasting.
a) Machining (lathing, milling, threading) is not a surface treatment method, but can be used to produce specific surface topographies and surface compositions. The properties of machined surfaces mainly depend on the work-piece speed, tool pressure and choice of lubricant.13-15
Machined dental implants (turned surface) were the first generation of dental implants described by Branemark. Although the surface appears to be relatively smooth, scanning electron microscopy (SEM) analysis showed grooves and ridges created during the manufacturing process.
One disadvantage regarding the morphology of non-threaded (machined) implants is that the surface defects provide resistance to bone interlocking, which delays the process of osseointegration as a result of osteoblastic growth along the existing surface grooves.
b) Grinding and mechanical polishing are identical methods in that they remove some of the surface material by using a hard abrasive.
Grinding involves use of coarse particles as abrasive medium to remove the surface at a faster rate. Grinding creates relatively rough surface topographies. Grinding with an abrasive grade 60 leads to Ra values around 1μm, and with the coarsest grade the surface roughnesses of up to 5-6 μm can be achieved.
c) Grit blasting also known as abrasive blasting, is another technique which is used to create surface topographies on the implant surfaces. In grit blasting, surface of the implant is bombarded with hard dry particle or particles suspended in a liquid at high velocity. Various types of ceramic particles such as alumina, silica, etc. of different sizes can be used for grit blasting of titanium.. Examples: DENTSPLY Implants, ASTRA TECH TiOblast, Zimmer Dental MTX, Glidewell Inclusive Tapered implants.
Chemical treatments
The chemical methods of implant surface modifications include chemical treatment with acids or alkali, hydrogen peroxide treatment, sol-gel, chemical vapor deposition and anodization. Chemical surface modification of Titanium (Ti) has been widely applied to alter surface roughness and composition and enhance wettability/surface energy. The process of acid treatment serves to remove the surface oxide and contamination which leads to a clean and homogenous surface. The acids commonly used include hydrochloric acid, sulfuric acid, hydrofluoric acid and nitric acid.
Implant surfaces can be modified by chemical treatments such as solvent cleaning, wet chemical etching, and passivation.
Example: BIOMET 3i OSSEOTITE and NanoTite, Nobel Biocare TiUnite
a) Solvent cleaning is mainly aimed at cleaning the surface of the implant from oils, greases and fatty surface contaminants remaining after manufacturing process by using organic solvents (aliphatic hydrocarbons, alcohols, ketones or chlorinated hydrocarbons), surface active detergents and alkaline cleaning solutions. For affective cleaning the process may be carried out at elevated temperatures with or without the use of ultrasonication. This process does not have any effect on the surface of the implant.
Selection of a solvent is based on the type of material to be cleaned and type of contamination to be removed from the material.
b) Wet chemical etching dissolves the native surface layer of the implant material including the oxide layer and parts of the underlying metal to improve the surface roughening as well as for producing an aesthetically favourable surface finish. Because the titanium dioxide on the surface of the implant is a stable one, choice of etchants is limited to few acids and alkaline solutions.
Acid etching or pickling is used for removing oxide layer to obtain clean and uniform surface finish. The most commonly used etching solution is an aqueous mixture of 10-30 volume % of nitric acid; (69 mass%) and 1-3 volume% of hydrofluoric acid (60 mass%).
Examples: BIOMET 3i OSSEOTITE and NanoTite.
The dual acid-etched surface produces a microtexture rather than a macrotexture. It has been found that dual acid-etched surfaces enhance the osteoconductive process through the attachment of fibrin and osteogenic cells, resulting in bone formation directly on the surface of the implant.
Sandblasted and acid-etched surface implants (SLA and modified-SLA). The SLA implant surface is produced after sandblasting with large grit particles of 250–500 μm followed by etching with acids.
Example: CAMLOG Promote, DENTSPLY Implants FRIALIT and FRIADENT plus, Straumann SLA.
Alkaline etching is a simple technique to modify the titanium surfaces. Treatment of titanium in 4-5 M sodium hydroxide at 600oC for 24 hours has been shown to pro-duce sodium titanate gel of 1 μm thick, with an irregular topography with high degree of open porosity. Composition and structure of this layer can be further modified by proper heat treatment. Alternatively, boiling alkali solution (0.2 M sodium hydroxide, 1400 oC for 5 h) can be used to produce a high density of nanoscale pits on the titanium. When the alkali treatment is preceded by etching in hydrochloric acid/sulfuric acid, porosity of the final surface is found to increase.
c) Passivation treatments are used for obtaining a uniformly oxidized surface to improve corrosion resistance. It is often the last step in the surface preparation of the implants. Immersion of the titanium for a minimum of 30 minutes in 20-40 vol% solution of nitric acid at room temperature is the most commonly employed method.
Physical methods
The physical methods of implant surface modification include plasma spraying, sputtering, and ion deposition.16,17
a) Plasma spraying is a method where particles, HA or Ti are projected on the surface through a plasma torch at very high temperature.. Examples: Straumann ITI titanium plasma sprayed (TPS).
b) Sputter deposition( Sputtering ) is a vacuum process whereby molecules of a material are ejected by bombardment of high-energy ions to improve their biocompatibility, biological activity, and mechanical properties such as wear resistance and corrosion resistance
The disadvantages of sputter coating are time consumption, produces amorphous coatings and Ca/P ratio of the coating is higher than of synthetic HA. There are several sputter techniques and a common drawback inherent in all these methods is that the deposition rate is very low and the process itself is very slow.
c) In electro-polishing technique, a controlled dissolution of the surface takes place under the influence of electrochemical reaction. Choice of the electrolyte is generally a mixture of an acid and alcohols (60 ml perchloric acid and 350 ml n-butanol, and 540 ml methanol held at 25 °C or lower) for titanium.
d) In Ion implantation method, surface of the implant is bombarded with high energy ions (approximately 100 KcV to 1 McV range). Ions will penetrate the surface of implant to typical depths of approximately 0.1-1 μm
NANO-ROUGHNESS AND NANOSTRUCTURES
All surfaces possess nano-roughness, however not all of them have defined nanostructures. Nanostructured materials are defined in the literature as materials containing structural elements with dimensions in the range of 1-100 nm.
SOME METHODS TO ALTER NANOTOPOGRAPHY
Sol-gel coatings
During the sol-gel process, a liquid with a specific composition (i.e., the Sol) is converted into a solid gel phase. Thin coatings can be deposited onto a surface by dip- or spin coating techniques. The procedure makes it possible to produce coatings of Ti, HA or combination of both.18
Nanocrystalline HA coatings
Nanoparticles of HA is prepared by mixing H3PO4 and Ca (NO3) to a Ca/P ratio of 1.67 in the presence of a liquid crystalline phase. The crystalline phase limits particle growth to ~5 nm. When HA particles have formed, the liquid crystalline phase is dissolved and the particles can be deposited onto a surface using dicyandiamide.
BIOLOGICALLY ACTIVE DRUGS INCORPORATED DENTAL IMPLANTS
Some osteogenic drugs have been applied to implant surfaces. Incorporation of bone antiresorptive drugs, such as bisphosphonate, might be very relevant in clinical cases lacking bone support.19
Bisphosphonates
Bisphosphate-loaded implant surfaces have been reported to improve implant osseointegration. Bisphosphonate incorporated on to Ti implants increased bone density locally in the peri-implant region with the effect of the antiresorptive drug limited to the vicinity of the implant.
Simvastatin
Simvastatin, could induce the expression of bone morphogenic protein (BMP) 2 messenger ribonucleic acid that might promote bone formation. In an in vitro study Yang et al (2010) showed that simvastatin-loaded porous implant surfaces promote accelerated osteogenic differentiation of preosteoblasts, which have the potential to improve the nature of osseointegration.
Antibiotic coating
Gentamycin along with the layer of HA can be coated onto the implant surface, which may act as a local prophylactic agent along with the systemic antibiotics in dental implant surgery.
Tetracycline-HCl functions as an antimicrobial agent capable of killing microorganisms that may be present on the contaminated implant surface. It also effectively removes the smear layer as well as endotoxins from the implant surface. Further, it inhibits collagenase activity, increases cell proliferation as well as attachment and bone healing. Tetracycline also enhances blood clot attachment and retention on the implant surface during the initial phase of the healing process and thus promotes osseointegration.
MICROGEOMETRY OF COMMERCIALLY AVAILABLE IMPLANT SYSTEMS
LASER-LOK Microchannels
- Exclusively from BioHorizons, Laser-Lok is the only surface treatment shown to attract a true, physical connective tissue attachment.
- Laser-Lok is a series of precision-engineered cell-size channels laser-machined onto the surface of dental implants and abutments.
- Multi-center prospective study showing only 0.59mm of bone loss compared to 1.94mm for traditional implants. Overdenture study showing only 0.42mm of bone loss compared to 1.13mm for NobelReplace Select.
- Laser-Lok microchannels is a proprietary dental implant surface treatment developed from over 25 years of research initiated to create the optimal implant surface. Through this research, the unique Laser-Lok surface has been shown to elicit a biologic response that includes the inhibition of epithelial downgrowth and the attachment of connective tissue. This physical attachment produces a biologic seal around the implant that protects and maintains crestal bone health. The Laser-Lok phenomenon has been shown in post-market studies to be more effective than other implant designs in reducing bone loss.
- Laser-Lok microchannels is a series of cell-sized circumferential channels that are precisely created using proprietary laser ablation technology. This technology produces extremely consistent microchannels that are optimally sized to attach and organize both osteoblasts and fibroblasts. The Laser-Lok microstructure also includes a repeating nanostructure that maximizes surface area and enables cell pseudopodia and collagen microfibrils to interdigitate with the Laser-Lok surface.
- XPEED
- MegaGen has developed surface treatment based on S-L-A technique with nano layer of Ca2+ incorporated.
- Ion creates a CaTiO3 nanostructure on the surface, and activates osteoblasts in the live bone. The name of this unique specialized surface treatment is XPEED.
- MICRO-ROUGH IMPLANT SHOULDER
- The patented microstructured implant shoulder by Ankylos (Dentsply Sirona) allows for bone formation up to the abutment. This supports the overlying soft tissue and establishes optimized conditions for long-term tissue stability and health.15,16,18,20
ADVANTAGES AND DISADVANTAGES OF COATINGS
THE CLINICAL ADVANTAGES OF TPS OR HA COATINGS MAY BE SUMMARIZED AS THE FOLLOWING:
- Increased surface area
- Increased roughness for initial stability
- Stronger bone-implant interface
ADDITIONAL ADVANTAGES OF HA OVER TPS INCLUDE THE FOLLOWING:
- Faster-healing bone interface
- Increased gap healing between bone and HA
- Stronger interface than TPS
- Less corrosion of metal
THE DISADVANTAGES OF COATINGS INCLUDE THE FOLLOWING:
- Flaking, cracking, or scaling on insertion
- Increased plaque retention when above bone
- Increased bacteria and nidus for infection
- Complication of treatment of failing implants
- Increased cost
CONCLUSION
In the 1960s dental implantology as a clinical discipline was judged by some to be rather disorganized, and treatments provided were often said to be not as successful as hospital-based orthopedic and cardiovascular surgery procedures.
One part of this opinion related to the use of standard intraoral dental materials for implants plus general dental operatories for surgical activities (e.g., no gloves, high-speed drills, tap water).
The biomaterials discipline evolved rapidly in the 1970s.
Successful uses of synthetic biomaterials have been based on experience within the field of dental implantology.
The basis for many of the newer and more clinically successful surgical reconstructions evolved within dentistry, with some now recognized as the most successful types of musculoskeletal reconstructive surgery.
The biomaterials discipline therefore has evolved significantly over the past decades, and synthetic biomaterials are now constituted, fabricated, and provided to health care professionals as mechanically and chemically clean devices that have a high predictability of success when used appropriately within the surgical disciplines.
Surface characterization and working knowledge about how surface and bulk biomaterial properties interrelate to dental implant biocompatibility profiles represent an important area in implant-based reconstructive surgery.
REFERENCES
- Misch C. Dental Implant Prosthetics. 2nd ed. Elsevier Health Sciences; 2008.
- Anil S, Anand PS, Alghamdi H. Dental Implant Surface Enhancement and Osseointegration. Implant Dentistry ï€ A Rapidly Evolving Practice.2000:84-108.
- Dhaiya V, Shukla P, Gupta S. Surface topography of dental implants: a review.J Dent Implant.2014;4(1):66-71.
- 2. Lesmes D. Innovations in Dental Implant Design for Current Therapy. Dent Clin N Am 2011; 55: 649-661.
- Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthopaedica Scandinavica. 1981;52(2):155-70.
- Kilpadi DV, Lemons JE. Surface energy characterization of unalloyed titanium implants. J. Biomed. Mater. Res. Part A. 1994;28(12):1419-25.
- Zhao X, Liu X, Ding C. Acidâ€Âinduced bioactive Titania surface. J. Biomed. Mater. Res. Part A. 2005;75(4):888-94.
- Buser, D.; Nydegger, T.; Oxland, T, et al. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs. J. Biomed. Mater. Res.1999; 45: 75-83.
- Cochran DL, Buser D, Ten Bruggenkate CM, Weingart D, Taylor TM, Bernard JP, Peters F, Simpson JP. The use of reduced healing times on ITI® implants with a sandblasted and acidâ€Âetched (SLA) surface. Clin Oral Implants Res. 2002;13(2):144-53.
- Barfeie A, Wilson J, Rees J. Implant surface characteristics and their effect on osseointegration. Br dent J. 2015. 13;218(5):E9.
- Junker R, Dimakis A, Thoneick M, Jansen JA. Effects of implant surface coatings and composition on bone integration: a systematic review. Clinical oral implants research. 2009;20(s4):185-206.
- Shalabi MM, Gortemaker A, Hof MV, Jansen JA, Creugers NH. Implant surface roughness and bone healing: a systematic review. J. Dent. Res. 2006;85(6):496-500.
- Kieswetter K, Schwartz Z, Dean DD, Boyan BD. The role of implant surface characteristics in the healing of bone. Crit Rev Oral Biol Med. 1996;7(4):329-45.
- Alla RK, Ginjupalli K, Upadhya N, Shammas M, Ravi RK, Sekhar R. Surface roughness of implants: a review. Trends in Biomaterials and Artificial Organs. 2011;25(3):112-8.
- Ellingsen JE, Thomsen P, Lyngstadaas SP. Advances in dental implant materials and tissue regeneration. Periodontology 2000. 2006;41(1):136-56.
- Bowers KT, Keller JC, Randolph BA, Wick DG, Michaels CM. Optimization of surface micromorphology for enhanced osteoblast responses in vitro. Int J Oral Maxillofac Implants. 1992;7(3).
- Wieland M, Chehroudi B, Textor M, Brunette DM. Use of Tiâ€Âcoated replicas to investigate the effects on fibroblast shape of surfaces with varying roughness and constant chemical composition. J Biomed Mater Res Part A. 2002;60(3):434-44.
- El-Gammal MY, El-Gammal NY, Fadhil ON, Maria OM. Biological reactions to different dental implant surface treatments. Int J Contemp Dent Med Rev. 2015:1-9.
- Galli C, Guizzardi S, Passeri G, Martini D, Tinti A, Mauro G, Macaluso GM. Comparison of human mandibular osteoblasts grown on two commercially available titanium implant surfaces. Journal of periodontology. 2005;76(3):364-72.
- Bornstein MM, Valderrama P, Jones AA, Wilson TG, Seibl R, Cochran DL. Bone apposition around two different sandblasted and acidâ€Âetched titanium implant surfaces: a histomorphometric study in canine mandibles. Clin Oral Implants Res. 2008;19(3):233-41.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Prerna Kaushik, Dr. C. Pradeep, Dr. Siddharth Sisodia. Micro Geometrical Considerations in Dental Implants. Guident. 2021 Jun;14(7). Available from: https://guident.net/articles/prosthodontics/micro-geometrical-considerations-in-dental-implants.html