Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net
Open AccessReviewProsthodontics

Role of Laboratory- Made Precision Attachments in Prosthodontics

  • Dr. Sai Swethaa S Dr.Sunil Dhaded Department of ProsthodonticsP.G Student

AMEs Dental College & Hospital, Raichur, India

Guident · Volume 11, Issue 5 (April 2018)Published April 201816 min read29 figures

ABSTRACT

Our ever-increasing knowledge of the oral environment, together with technological improvements and good armamentarium materials should give a restoration which is esthetically pleasing and comfortable. Today's practitioners are provided with changing techniques and a better understanding of the oral environment. This makes it all the more important to reconcile what is actually feasible with the patient's own expectations.

Key words: attachments, applications, advantages, disadvantages, laboratory attachments

INTRODUCTION

An attachment is a connector consisting of two or more parts. One part is connected to a root, tooth or implant and the other part to prosthesis. Certain exceptions are some attachments have only one manufactured part and the other part must be made by the dentist or the dental technician.1

Attachment dentistry provides superior cosmetic and functional alternatives to the standard cast partial denture with clasps..Attachment system provides conventional treatment options for patients with a remaining anterior dentition and unilateral or bilateral edentulism. While functional loads are dispersed in a favorable manner for the abutment teeth, wear induced, loss of retention of matching attachment component plays a major role in the longevity of these restorations1

In recent years precision attachment has been used and continues to add versatility to the practice of dentistry.

Attachment applications includes 1,2

• Crown and bridge restorations

• Partial denture restorations

• Over denture restorations

• Implant restorations

A precision attachment always consists of two functional units although each functional unit may consist of several parts too. One functional part is the primary part, incorporated into the abutment construction, and the other is the secondary part, built into the removable appliance, bridge, partial denture, or full denture.

Frictional wall precision attachment partial dentures (precision bridges) are indicated in most partial denture situations. In mouths with missing teeth, the first question should be: Is a fixed partial denture indicated? If a removable partial denture is indicated, then consideration should be given to the precision partial denture over the clasp-type partial denture. The precision partial denture is indicated in the following situations:

Indications

Contraindications

1.Long-span replacements

1. Teeth with short clinical crowns (this can be overcome with periodontal surgery

2.As stress breaker in Free-end saddles

2. Teeth that are narrow faciolingually.

3.Periodontal involvement that

contraindicates fixed partial dentures

3. Teeth that have extremely large pulps (young people).

4.Situations requiring maximum esthetics

4. Any patient who has a contraindication for a partial denture (health, non- cooperative}

5.Movable joints in fixed movable bridge work

5. Patient’s lack of dexterity or ability to use the hands.

6. As contingency devices for the extension or conversion of existing fixed appliances.

6.Periodontitis

7. Sections of a fixed prosthesis may be connected with intra coronal attachments

7. Abnormally high caries rate

Advantages

Disadvantages

  1. The longevity and prognosis of the abutment is improved with increased patient satisfaction

Complexity of design, complex principles and procedures for fabrication and clinical treatment. Minimum abutment occlusogingival height of 4-6 mm is necessary depending on the attachment system used.

  1. Improved esthetics and elevated psychological acceptance of the prosthesis as conventional clasp assemblies and rests may be visible and unaesthetic

Expensive – increased overall cost of the treatment.

Mechanical benefit in the intracoronal attachment. Because the attachment resides within the normal anatomic contours of the abutment teeth functional forces and loads are directed more favorably along the long axis of the teeth and more apically.

Because of complexity of the laboratory and clinical procedures involved in the construction of attachment retained prosthesis.

Attachment maintenance (repair or periodic replacement)

Attachment components will wear because of friction between metal parts overtime and may require repair or replacement. Requires high technical expertise for successful fabrication experience and knowledge on the part of dentist and laboratory technician are essential

The number of components of the denture is reduced and hence tolerance should be better

Cooperation and manual dexterity on the part of the patient.

Increased demand on oral hygiene performance.

The number of components of the denture is reduced and hence tolerance should be better

Cooperation and manual dexterity on the part of the patient.

Increased demand on oral hygiene performance.

Compared to conventional clasp retained partial denture they give.

  • Better retention and stability.
  • Less liable to fracture than clasp.
  • More esthetic than clasp.

Less food stagnation.

Anatomy of tooth – Placement of attachments in the incisor and canine areas may pose difficulties because of limited faciolingual width.

The prefabricated precision attachment has the advantage of being fabricated from metal alloys which are harder and more wear-resistant

Aggressive tooth preparation is necessary to permit the placement of intracoronal precision attachment within the normal anatomic contours of the planned crown.

CLASSIFICATION OF ATTACHMENTS

Based on method of fabrication and the tolerance of fit3

  • I. Precision attachment (prefabricated types)
  • II. Semi-precision attachment (custom made / laboratory made types)

Clinical figureClinical figure

According to their relationship to the abutment teeth

  • I. Intra-coronal (Internal attachment) &
  • II. Extracoronal (External attachment)

Clinical figure

Based on stiffness of the resultingjoint

  • I. Rigid attachments & Resilient attachments (Non rigid)

Clinical figureClinical figure

MC Mensor (1973)4

An attachment classification according to shape, design and primary area of utilization of attachment.

Coronal

Radicular

Accessory

Intracoronal

Telescope

Auxiliary

Extracoronal

(Pressure buttons)

Screw units

Bar attachment

Bar connectors

(Bar joints and bar units)

Bolts

Stabilizers

Balances

Gerardo Beccera and others (1987)5.6

Intra dental attachment

  • - Frictional
  • - Magnetic

These are contained in part within the crown or root structure of a natural tooth.

Extra dental attachments.

  • - Cantilever attachment.
  • - Bar attachment.

Good kind and Baker 1976 7

Intracoronal

a) Resilient

b) Non resilient

Extracoronal

c) Resilient

d) Non resilient

Prefabricated types (precision attachment):

Typically consist of precision milled male-female assembly . Components are fabricated in metal using high precision manufacturing technique. These attachment usually exhibit long, parallel walls and exceptional surface adaptation. Tolerance between accurately fitting components of an intracoronal precision attachment is so fine that the retention results from the frictional fit.

Laboratory made types (Semi precision attachment)

Components usually originates as prefabricated / manufactured pattern (wax or plastic nylon) hand waxed inserts which are then incorporated in the wax pattern, invested, eliminated and casted in metal. Or alternative method (hand waxed) of fabrication is to use a tapered metal mandrel (Ti- con mandrels).Semi precision attachment often display gently tapering walls for ease of fabrication. Less intimate fit between matrix and patrix component.

- Because of the inaccuracies inherent in their fabrication, most laboratory made attachments have limited amount of frictional retention compared to the commercially available precision attachments.

Classification by Harold Prieskel:8

1. Intracoronal attachments:

A. Those whose retention is entirely frictional

With adjustment potential: Constant insertion and removal of the prosthesis will cause the attachments to wear, so that some form of adjustment is desirable. e.g.:

a. Chayes attachment

b. Crismaniattachments.

c. McCollum unit

d. Ancra attachment.

e. T-Geschiebe

Clinical figure

Fig a

Clinical figure

Fig c

Clinical figure

Fig e

LABORATORY-MADE PRECISION ATTACHMENTS

In Europe, laboratory-made attachment became known during the First World War, when ready-made attachments fromthe United States were unobtainable. At the time, for a dentist to make his own attachments was quite a feat, since casting methods were still in a rudimentary stage. One of the great pioneers in laboratory-made attachments was Alfred Steiger, who, by his ingeniousness and careful planning, created a class of attachments unparalleled in durability and variability. His inventions, with slight modifications have survived into our modern times and still count in among the best retainers we have.

SLIDING ATTACHMENTS

Sliding attachments provide rigid, removable anchorage. Their components are geometric bodies that can be slid one into the other with a precision fit. There is only one path of insertion and a definite terminal stop (limited axial movement attachment9.

SLIDING CAP ATTACHMENT

A sliding cap attachment consists of a cylindrical or conical primary part and a cap-shaped secondary part, which slides over the primary part.The best-known type of sliding cap attachment is the double crown. A double crown consists of a fixed inner coping and a removable outer crown. The interface between coping and crown may be either parallel-sided (telescopic crown) or tapered (konus crown)10.

TELESCOPIC CROWNS

Telescopic crowns are laboratory-made double crowns, with the primary crown cemented tothe abutment tooth and the secondary crown soldered to the removable bridge or partial denture. Parallelism between abutment preparations must be approximated though a slight discrepancy may be corrected in the cutting of the primary crowns. This principle may be used also in fixed bridgework, where the frequent case of convergent abutment teeth in a mandibular lateral bridge may pose a difficult problem to the practitioner. The danger of pulp exposure on a tipped tooth prepared to receive a crown is well known. With a primary crown cemented into place, the fixed bridgework may be easily cemented without previous parallelization of the abutment preparations.

Likewise, removable prosthetic work may be retained by telescopic crowns. If the walls of the contacting crown surfaces are near parallel, this parallelism is a sound retention for a longtime. However, such parallel crowns are difficult to separate. In other words, the patient often has difficulty removing his appliance. Therefore a certain conicity of 2 to 4 degrees is preferable. Conic crowns however are non- retentive so elastic elements must be incorporated into them. Such elements are the pins of the CSP attachment, which can be incorporated in to the crowns. Slight activation of these pins restores the frictional retention lost by wear. Another means of retention of telescopic crowns is a spring attachment. Such springs are incorporated in to the inside wall of the removable crowns and upon insertion snap over a slight on the cemented crown. To avoid over-contouring of telescopic crowns, an accentuated chamfer preparation is recommended. This creates enough space so that the outer retainer crowns can be formed within the approximate dimension of the original teeth.

Clinical figureClinical figure

Clinical figureClinical figure

In a telescopic crown attachment, the interface between the outer crown and the inner coping is cylindrical with frictional areas that are virtually parallel. Constant contact occurs between the two parts as they are slid together to the terminal position.

A typical application of this is in the case of a patient with a large anterior bony defect, caused by an accident. A telescopic prosthesis is also an excellent treatment for any interrupted dental arch having short clinical crowns 10.

HYBRID TELESCOPE CROWN

A special type of telescopic crown is the so called hybrid telescope. Friction is increased by placing axial grooves (increased surface area) and internal clip pins (spring loading). A small depression placed under the pin on the inner surface of the crown makes it easier to activate.

Clinical figureClinical figure

Clinical figure

Where a long span and short clinical crowns make the success of a purely tooth-borne fixed bridge doubtful, a removable bridge with mixed support and hybrid telescopes can be used as a most successful alternative10.

RING TELESCOPE

Clinical figure

Clinical figure

Inner aspect of the mixed support bridge with clip pins in the anterior outer crown the molar is fitted with a conventional ring telescope. With this design, almost the entire length of the molars axial walls can be maintained and utilized as the frictional zone. This type of telescopic attachment is especially recommended for short clinical crowns

MODIFICATION OF THE RING TELESCOPE

Clinical figure

Clinical figure

A Modification of the ring telescope with a mesio- distal strut used to reinforce the hybrid telescope

KONUS CROWN

A konus crown is a double crown with a conical interface. Its frictional grip does not take effect until the outer removable crown is completely seated over the inner fixed coping. A wedging effect can be achieved in the terminal position if the convergence angle is properly selected.

Clinical figure

Clinical figure

Clinical figure

A typical indication for konus crown is a dentition with several adjacent vital teeth having long clinical crowns and reduced attachment following periodontal treatment.

SLIDING PARTIAL CAP ATTACHMENT

In a sliding partial cap attachment the secondary part encompasses the primary part only partially. The primary part is a full or partial veneer crown into which the negative form of the secondary part has been milled. Surface area and retention are increased with vertical grooves that also serve as seating guides. In addition, the grooves secure the structure against horizontal forces (thrust and torsion). A cervical or occlusal shoulder acts as a terminal seating stop. The most familiar representative of sliding partial caps is the shoulder-groove-pin sliding attachment. The addition of pins enhances the resistance to tensile forces.10

SHOULDER-GROOVE SLIDING ATTACHMENTS

The axial seating grooves are united by an occlusal offset or shoulder to form a U shaped internal frame work. This strengthens the removable part of the retainer and prevents its walls from spreading apart under functional loads.10

Clinical figure

Clinical figure

Shoulder-groove sliding attachments

SHOULDER-GROOVE- PIN SLIDING ATTACHMENTS

Shoulder-groove- pin sliding attachments as used today almost always have the clip pins placed peripherally rather than near the center of the tooth. Thus, they can be used on vital teeth without excessive sacrifice of tooth structure or risk to the pulp. Another advantage is the ease with which the pins can be activated. Here, too, the pins should be protected during insertion of the prosthesis by long axial seating grooves.

Clinical figure

Clinical figure

Shoulder-groove- pin sliding attachments

CHANNEL-SHOULDER-PIN ATTACHMENT (STEIGER)

The channel – shoulder pin attachment (CSP) is a laboratory – made attachment and may be adapted to all conceivable crowns, overlays, inlays, porcelain - to- gold crowns, and vital or non-vital teeth. If, properly constructed. The CSP is so resistant to wear and tear that it may claim to survive the tooth or the patient. A variation to the CSP attachment is a Steiger bar attachment, an extra coronal attachment. Both these attachment consist of three elements as the name suggests: The channels elements that guide the matrix on to the patrix into its seat; the shoulder a supporting element receiving and transmitting shearing forces or axial stress, and last the pins, which provide the frictional element. They oppose a reasonable measure of resistance to the separation of the matrix and the patrix. Naturally, the proper design of the attachment body is paramount for success. Faulty design has led, in dental practice, to most of the failures observed. Since there is no limit to the possibilities of design, they are subdivided into three main groups A rule is established for all of them. The design must be such that the matrix (without the frictional pins) must not be displaceable except in the direction of removal and insertion. Even if strong lateral forces or torque are applied, there should not be the slightest movement between patrix and matrix.

Clinical figure

The three basic designs of the CSP attachment are: cylinder, horseshoe, and T. The most resistant design is the cylinder in all its variation. It applies to full crowns, three-quarter crowns, overlays, and post crowns.

The horseshoe design applies mainly to porcelain-to-gold crowns without occlusal gold surfaces. A modification of the horseshoe design has been adopted by Gaerny for his CIS attachments (removable closure of the interdental space). Such horseshoe type of attachments must be made very strong in order to avoid “opening” of the attachment on the open end, by torque. Also, a dovetail junction of continuous attachments or deep channels on single abutment attachments must keep proper retention.

The T design has been all but abundant, because it is the weakest of all. It may be used on an end standing abundant tooth as supplementary attachments. For example on the mesial of a single molar bridge apartment it is just as easy though to cut a modified cylinder attachment 10.

Clinical figure

Clinical figure

THE SEMI-PRECISION REST

An occlusal rest provides tooth support for a partial denture. Most rests are designed to transmit forces applied at about right-angles to the occlusal surfaces, but the direction of forces which can be transmitted to the teeth is decided by the rest seat preparations. When an abutment tooth is so be crowned, the rest seat can he deepened and con toured to the operator’s requirements. Rest seats with minimal taper, result in additional guiding planes for the removable prosthesis. As the rest seat is deepened, the ability to transmit lateral forces is increased until the bracing action may be considerable. In these circumstances it is possible to dispense with a bracing arm and to construct a unit consisting of a rest and a retaining arm.

Semi-precision rests may be carved in wax with the aid of a surveyor and then produced in the laboratory. The surveyor is more commonly used to align preformed wax or metal rest seat patterns as this is usually more convenient, the pattern is burnt out or dissolved before the crown is cast. The crown can then be milled to improve the surface of the rest seat. The male section of the unit is normally cast as part of the framework of the denture. The design and positioning of the occlusal rest influence the functions it will serve. Blatterfein (1969) has suggested that the design be considered from four aspects, proximal form, occlusal form, gingival floor form, and proximal surface placement.

The depth and taper of the rest seats are import ant considerations of the proximal form. If some measure of retention together with bracing action is required, the rest seat depth should not be less than 3 mm, and the convergence of the lateral walls should not exceed 5 degree. Increasing the angle of convergence of the walls facilitates insertion and removal of the prosthesis, but decreases the bracing and retentive action of the unit. These properties are rapidly reduced as the rest seat depth increases.The occlusal outline is basically rectangular. For strength and ease of manufacture, a neck width of not appreciably less than 3mm. is recommended, unless a prefabricated unit is employed. A rectangular shape does not resist displacement of the prosthesis away from the abutment tooth. This movement may be resisted by inclined lateral walls, although this complicates the production of the unit. Circular or dovetail forms may be used but will play little part in preventing lateral rotation or whip, of a distal extension prosthesis. Constructional and cleaning difficulties normally dictate the use of a flat gingival floor but inclined and channeled floors do provide additional resistance to displacement .Retention is often provided by a lingual arm. This lingual arm can be recessed within the contour of the abutment crown but, unlike the bracing action of a precision attachment, the tip of this arm has t0 be flexible to engage an undercut. The rigid section of this lingual retainer does, however, contribute of the prosthesis and serves to protect from wear the lateral surfaces of the rest.

Prefabricated retentive devices such as the Tach- E-Z and C and L systems are available. A neat laboratory-produced system can also be employed but lacks the stability afforded by the lingual arm. As a result it may need frequent adjustment to maintain retention. Koper (1973) has refined the Thompson dowel attachment and described other similar units.

Semi-precision rests are simpler and more economical to employ than precision attachments.They require the preparation of few abutment teeth and allow the operator to design the unit for a particular situation- A partial or full coverage restoration is normally required in conjunction with a shoulder preparation. The full width of the shoulder should be carried through the proximal surfaces and carried onto both lingual and buccal surfaces. The semi-precision rest is neat, effective and versatile. It should be considered for use where neither the clasp nor the attachment retainer is entirely suitable11.

SUMMARY

This an overview of precision attachment that have been fabricated over a long period of time with emphasis on the more commonly used and available ones. The number of precision attachment that has been used over the last two centuries is staggering, however many of these were developed for individual situations rather than for common usage. Current trends show an increase in usage of precision attachment especially those involving milled prosthesis which aid in giving better function and are less prone to failure. However each manufacturer gives specific instructions and accessories for the mounting and replacing process of the whole or of parts of the attachment. Laboratory made attachments seem to be of the most resistant types to wear and tear. The CSP (channel – shoulder- pin) attachment and the bar attachments particularly fit this description. These attachments properly designed and made, outlive the teeth to which they are fixed or the patient who wears them.Readymade attachments, particularly telescope studs, have replaceable parts and with proper service, are also durable constrictions.

Planning of precision attachment work is very important along with the knowledge of the special indication and limits of each attachment. Also the mechanics of movement in removable bridge work, partial denture work and over denture work must be known by the practitioner or else he will face frequent failures

REFERENCES

  1. Holst S, Blatz MB et al. In vitro wear of different material combinations of Intracoronal Precision Attachments. Int J Prosthodont 2006; 19: 330-32.
  2. Jenkins G. Precision Attachments – a link to successful restorative treatment.
  3. David R. Burns. Classification and selection of attachments. IJP 1990;3(2):58-61
  4. Mensor MC. Classification and selection of attachments. J Prosthet Dent 1973; 29: 494-97.
  5. Amit Khare, SumitMakkar, Roshna T. Full Mouth Rehabilitation with Fixed and Removal Prosthesis using Extracoronal Attachments: A Clinical Report. People’s Journal of Scientific Research Vol. 4 (2), July 2011
  6. Gerardo Becerra, Micheal Mac Entee. Classification of precision attachments. J Prosthet Dent 1987; 58 (3): 322-327
  7. Rudd KD, Morrow RM, Eissmann HF – Dental Laboratory Procedures – Removable Partial Dentures. St. Louis, Missouri: CV Mosby; 1986 .
  8. Preiskel HW. Precision Attachments in Dentistry. 3rd ed. London: Henry Kimpton; 1979.
  9. Brodbelt RHW. A simple paralleling template for precision attachments J Prosthet Dent 1972; 27: 285-288
  10. Zahler JM. Symposium on Stable Base Precision Attachment Removable Partial Dentures DCNA Vol. 24, No.1 Jan 1980.
  11. George Graber-Colour Atlas of Dental Medicine- Removable Partial Dentures. Vol. 2.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Sai Swethaa S Dr.Sunil Dhaded Department of Prosthodontics. Role of Laboratory- Made Precision Attachments in Prosthodontics. Guident. 2018 Apr;11(5). Available from: https://guident.net/articles/prosthodontics/role-of-laboratory-made-precision-attachments-in-prosthodontics.html

Related articles

More in Prosthodontics

All 444 articles
Vol. 11, Issue 5 · April 2018

3-D Printing in Head & Neck Region

3 D printing is a phrase used to describe the process of creating 3 objects from digital file using a material printer, in a manner similar to printing images on paper. The application of…

Dr . Saumya Gupta

Vol. 11, Issue 5 · April 2018

Teaming Up with Your Dental Laboratory!

The field of dentistry is evolving rapidly and there have been tremendous advancements in technology and material in the recent years, at the same time there is an increase in the patient’s…

Dr. Nitesh Shetty

Vol. 11, Issue 4 · March 2018

A PEEK into PEEK-an Innovative Biomaterial

Newer treatment modalities, materials and techniques have not only expanded the dental literature but also the prosthodontic treatment alternatives available to dentist and their patients…

Dr. Sonu Elsa John

Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.